CS ZON E REP OR TING OP TI ONS (ADDRESS 0358- 0389)
ADDRESS 0358-0365
CONTROL PANEL ZONES REPORT CODE
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8
0358
0359
0360
0361
Default for Group Zone Report Codes depends on Easy Menu Question "RCVR. FORMAT".
ZONE REPORT
CODE OPTIONS
DATA ENTRIES
DATA
ENTRIES
MODEM CODE
LEFT
1
Fire
2
Panic
3
Burglary
4
Hold up
7
Gas Alarm
8
Heat Alarm
0
Auxiliary Alarm
B
24 Hour Auxiliary
CS AREA & SYS TEM R EPOR TIN G OPTION S (ADD RESS 0391, 0392 & 0394)
LEFT DATA
AREA
VALUES
#
)
(CIRCLE
AREA 1
1
RESERVED
2
RESERVED
4
RESERVED
8
CS System Report Options
0394
Option
Default
1
OFF
OFF
2
3
OFF
OFF
4
OFF
5
OFF
6
OFF
7
OFF
8
L
NAPCO Security Systems
0362
0363
0364
0365
PULSE EVENT CODE will be the first digit of the 2 digit reporting code. The second digit will be the
second digit of the reporting zone. For example, for zone 9 (address 0366), if the right digit is "3", then
the reporting code is "39". For example, for zone 15 (address 0372), if the right digit is "4", then the
reporting code is "45".
MODEM CODES determine the zone types reported for the following formats: SIA and ADEMCO Point ID.
!
1. Select the desired Modem Code for each zone from the table shown.
U
D
!
2. Press
or
to save.
DISABLE OPENING REPORTS
ADDRESS 0391
LEFT DIGIT (SUM
RIGHT DIGIT
OF DATA VALUES)
blank (•)
[Default = blank (•) blank (•)]
Backup Report on Telco 2
Touch-tone Dialing Only *
Touch-tone Dialing w/Rotary Backup *
RESERVED
Cancel Next Test Timer on any Report
Disable Wait for Silence
Disable Wait for Handshake
Disable Auto Dial Tone Detect
ADDRESS 0366-0369
ZONES REPORT CODE
ZONE 9 ZONE 10 ZONE 11 ZONE 12
0366
0367
0368
0369
LEFT DATA
AREA
VALUES
#
)
(CIRCLE
AREA 1
1
RESERVED
2
RESERVED
4
RESERVED
8
CS AREA & SYSTEM REPORTING OPTIONS:
!
1.
Select the desired option entering the
option number (1-8) for each digit.
!
2.
Enter corresponding option number in
address location.
NOTE: Dark shaded data value box shows op-
tion not available.
U
D
!
3.
Press
or
* NOTE: If neither Touch-tone Dialing nor
Touch-tone w/Rotary Backup is selected, then
system defaults automatically to Rotary Dialing.
Leave blank (•) to select Rotary Dialing.
X
GEM-P816 Programming Instructions
Page 21
ADDRESS 0370-0373
ZONES REPORT CODE
ZONE 13 ZONE 14 ZONE 15 ZONE 16
0370
0371
0372
DISABLE CLOSING REPORTS
ADDRESS 0392
LEFT DIGIT (SUM
RIGHT DIGIT
OF DATA VALUES)
blank (•)
[Default = blank (•) blank (•)]
to save.
!
0373