81131_7.book Page 69 Wednesday, March 17, 2004 3:59 PM
Chapter 5: Installing the ST4000+

Connecting to the control unit

Motor tube
Note: If the wheel is bent or the wheel drive is off center, the pin will
move up and down in the back plate slot. As long as the pin does not
hit the top or bottom of the slot, this pin movement will not affect the
drive unit's performance.
13. When you have checked alignment, fully tighten all four screws.
When you have attached the pedestal bracket, you need to connect the
wheel drive to the control unit. The drive unit is supplied with 4.5 m
(15 ft) of 2-core cable with a waterproof socket at one end.
1. Connect the socket to the plug on the wheel drive's motor tube:
remove the socket cover
pull back the plug cover
align the locking ring, plug and socket as shown below
push the plug firmly into the socket
turn the locking ring 90° clockwise
make the connection waterproof by pulling the plug cover
across so it protects the plug and socket
Note: To remove the plug, pull back the cover and turn the locking
ring 90° anti-clockwise. If you disconnect the socket for any reason,
always use the attached rubber cover to protect the socket.
Socket
Contact
Locking ring
Plug
Plug cover
(pulled back)
Socket cover