81131_7.book Page 47 Wednesday, March 17, 2004 3:59 PM
Chapter 5: Installing the ST4000+
47
6 ft (1.8 m)
4 ft (1.2 m)
4 ft (1.2 m)
D5383-1
Compass - recommended location for steel-hulls
Mounting
Fluxgate compass - orientation
CAUTION:
You must mount the fluxgate compass on a vertical bulkhead,
with the cable exiting at the base.
1. Hold the compass against the mounting location.
2. Mark the four mounting holes, then remove the compass.
1
3. Drill four pilot holes using a 3 mm (
/
in) drill bit.
8