Solenoid Hold-in Test
1.
See
Figure 5-14.
With test leads still connected in the
manner specified in the previous
TEST, disconnect solenoid motor terminal/battery
negative test lead (B) at negative battery post only;
reconnect loose end of this test lead to positive bat-
tery post instead.
a0170x5x
1
1.
Motor terminal
2.
Relay terminal
Figure 5-14. Hold-In Test
2.
Observe starter pinion.
a.
If starter pinion remains in pull-in position, solenoid
is working properly.
b.
If starter pinion does not remain in pull-in position,
replace the solenoid.
SOLENOID PULL-IN
2
Battery
Solenoid Return Test
1.
See
Figure 5-15.
With test leads still connected in the
manner specified at the end of the previous
HOLD-IN
TEST, disconnect solenoid relay terminal/
positive battery post test lead (C) at either end.
2.
Observe starter pinion.
a.
If starter pinion returns to its original position, sole-
noid is working properly.
b.
If starter pinion does not return to its original posi-
tion, replace the solenoid.
a0171x5x
1
1.
Motor terminal
2.
Relay terminal
Figure 5-15. Return Test