Installation Checklist; Locating Your Gas Fireplace - Regency HZ33CE-NG Owners & Installation Manual

Hide thumbs Also See for HZ33CE-NG:
Table of Contents

Advertisement

INSTALLATION
CHECKLIST
1. Locate appliance:
a) Room location (Refer to "Locating Your
Gas fi replace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Mantle Clearances (Refer to "Mantel
Clearances" section)
d) Framing & Finishing Requirements
(Refer to "Framing & Finishing" section)
e) Venting Requirements (Refer to "Venting"
section)
2. Assemble Top and Side Standoffs (Refer to
"Unit Assembly Prior to Installation).
3. Slide unit into place.
4. Install vent (Refer to "Venting Arrangement"
sections).
5. Make gas connections (Refer to "Gas Line
Installation section).
6. Test the pilot (Refer to "Pilot Adjustment"
section).
7. Test Gas Pressure (Refer to "Gas Pipe Pres-
sure Testing" section).
8. Install 4 AA batteries in the battery pack or
optional AC power adaptor.
9. Install standard and optional features. Refer
to the following sections:
a)
Optional Refl ective Panels
b)
Glass Crystals or Optional Ceramic
Stones
c)
Remote Control or Wall Thermostat
d)
Optional Fan Assembly
e)
Optional 4 sided Faceplate
f)
Optional Mantel
10. Wall Mounted ON/OFF Switch:
Use the toggle wall switch supplied with the
manual package. Use of a "decor" switch
causes higher resistance which is a problem
on gas fi replaces.
11. Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly and operation fully explained to
customer.
Regency HZ33CE Gas Fireplace
This includes:
1. Clocking the appliance to ensure the correct
fi ring rate (rate noted on label), after burning
appliance for 15 minutes.
2. If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
LOCATING YOUR
GAS FIREPLACE
1. When selecting a location for your fi replace,
ensure that the clearances are met.
2. The appliance must be installed on a fl at,
solid, continuous surface For example a
wood, metal or concrete fl oor or in a raised (on
the wall) application. The appliance must be
installed on a metal or wood panel extending
the full width and depth of the appliance.
3. The HZ33CE Gas Fireplace can be installed
in a recessed position or framed out into the
room as in A, B, C and D. See Diagram 1.
A)
Flat on Wall
Diagram 1
B)
Flat on Wall Corner
C)
Recessed into Wall/Alcove
D)
Corner
INSTALLATION
4. This appliance is Listed for bedroom
installations when used with a listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
5. The HZ33CE Gas Fireplace is approved for
alcove installations, see "Clearances" section
for details.
6. We recommend that you plan your installation
on paper using exact measurements for
clearances and floor protection before
actually installing this appliance. Have an
authorized inspector, dealer, or installer
review your plans before installation.
Note: For vent terminations refer to "Exterior
Vent Termination Locations" section.
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hz33ce-lp

Table of Contents