Operating Instructions; First Fire; Lighting Procedure; Shutdown Procedure - Regency HZ33CE-NG Owners & Installation Manual

Hide thumbs Also See for HZ33CE-NG:
Table of Contents

Advertisement

OPERATING INSTRUCTIONS

OPERATING
INSTRUCTIONS
1. Read and understand these instructions
before operating this appliance.
2. Check to see that all wiring is correct and
enclosed to prevent possible shock.
3. Check to ensure there are no gas leaks.
4. Make sure the glass in the glass door frame
is properly positioned. Never operate the
appliance with the glass removed.
5. Verify that the venting and cap are
unobstructed.
6. The unit should never be turned off, and on
again without a minimum of a 60 second
wait.

FIRST FIRE

The FIRST FIRE in your heater is part of the
paint curing process. To ensure the paint is prop-
erly cured, it is recommended you burn your
fi replace for at least four (4. hours the fi rst time.
When fi rst operated, the unit will release an
odour caused by the curing of the paint and the
burning off of any oils remaining from manufac-
turing. Smoke detectors in the house may go off
at this time. Open a few windows to ventilate
the room for a couple of hours. The glass may
require cleaning.
NOTE: When the glass is cold and the appliance
is lit, it may cause condensation and fog
the glass. This condensation is normal
and will disappear in a few minutes as
the glass heats up.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS STILL HOT!
DO NOT BURN THE UNIT WITHOUT THE
GLASS DOOR IN PLACE.
During the fi rst few fi res, a white fi lm
may develop on the glass front as part of
the curing process. The glass should be
cleaned after the unit has cooled down
or the fi lm will bake on and become very
diffi cult to remove. Use a non-abrasive
cleaner and DO NOT ATTEMPT TO CLEAN
THE GLASS WHILE IT IS HOT.
50
50

LIGHTING PROCEDURE

1. Turn on ON/OFF switch or press and release
on ON/OFF button once on the remote
control if being used.
2. After approximately 4 seconds the spark
ignition system will spark for 60 seconds to
light the main burner.
3. The unit will turn on.
Note: The fi rst try for ignition will last approxi-
mately 60 seconds. If there is no fl ame igni-
tion (rectifi cation) the board will stop sparking
for approximately 35 seconds. After wait time
, the board will start second try for ignition
by sparking for approximately 60 seconds .
If there is still no positive ignition the board
will go into lock out.
The system will need to be reset as follows:
a) Turn the system off using ON/OFF switch
or press ON/OFF button - if using optional
remote.
b) After approximately 2 seconds turn on ON/
OFF switch or press ON/OFF button if using
optional remote.
c) Repeat step 1.
SHUTDOWN
PROCEDURE
1. Turn ON/OFF switch or press and release
the ON/OFF button once if using optional
Remote Control.
2. If service is to be performed - you must
disconnect both sources of power to the
unit, the main power and battery.
NORMAL OPERATING
SOUNDS OF
GAS APPLIANCES
It is possible that you will hear some sounds from
your gas appliance. This is perfectly normal due to
the fact that there are various gauges and types
of steel used within your appliance. Listed below
are some examples. All are normal operating
sounds and should not be considered as defects
in your appliance.
Burner Tray:
The burner tray is positioned directly under the
burner and is made of a different gauge material
from the rest of the fi rebox and body. Therefore,
the varying thicknesses of steel will expand and
contract at slightly different rates which can cause
"ticking" and "cracking" sounds. You should also
be aware that as there are temperature changes
within the unit these sounds will likely re-occur.
Again, this is normal for steel fi reboxes.
Pilot Flame:
While the pilot fl ame is on it can make a very
slight "whisper" sound.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will
expand and contract at different rates resulting
in some "cracking" and "ticking" sounds will be
heard throughout the cycling process.
Regency HZ33CE Gas Fireplace

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hz33ce-lp

Table of Contents