INSTALLATION
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium fl ex running
the full length of the chimney. See the "Venting
Arrangements - Vertical Terminations" Section
for minimum and maximum heights.
Required Parts:
Part #
Description
946-529
Co-linear DV Vertical
Termination Cap
948-305
3" Flex - 35 ft.
946-563
Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter
Outer Pipe
Inner Pipe Adapter
510-994
Rigid Pipe Adaptor
46DVA-E45 45
o
Elbow
Alternate Approved Caps
46DVA-VC
Vertical Termination Cap
46DVA-VCH High Wind Cap
46DVAGK
3" Co-linear Adapter with fl ashing
22
VERTICAL TERMINATION
WITH CO-LINEAR FLEX SYSTEM
Masonry chimneys may take various contours which the fl exible liner will accommodate. However,
keep the fl exible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
with Kit#
946-563
Pipe Length
Rigid Pipe Adaptor
# 510-994
Co-linear DV
Vertical Termination
Cap # 946-529
A maximum
of two certified
joiner kits
may be used
per length.
#948-305
35 ft (11m)
Exhaust
Flue
Outer
Pipe
o
45 Elbow
Inner Pipe
Adapter
with Kit#
946-563
Flex Liner
Air Intake
Co-Linear
Flex
Adapter
with Kit#
946-563
Regency HZ33CE Gas Fireplace