CLEAN FINISH

6. If applying a non-combustible facing it may be installed over the metal surface (clean front) of the unit in the area shown below.
NON COMBUSTIBLE BOARD SUPPLIED WITH UNIT
Combustible and Non-combustible Facing and Finishing
NOTE: The 3-1/2" x 34-9/16" non combustible material supplied with this unit can be replaced if trying to achieve a clean fi nish. A large piece of non com-
bustible material (ie. 4' x 8' x 1/2") can be used to eliminate taped seams on or near unit.
7. Non-combustible material (ie. tile, slate, etc.) may be brought up to the edge of the glass door of the unit. Minimum clearances must be adhered to, this
will assure ease of glass door removal and access to the lower panel.
NOTE: Non-combustible fi nishing materials may be of any thickness desired.
NON COMBUSTIBLE BOARD SUPPLIED WITH UNIT
No Combustible
Materials in this Area
NO FACING OR
FINISHING MATERIAL
IN THIS AREA
29-7/16"
747mm
2-1/2"
[64mm]
34-9/16"
878mm
Minimum Clearances for Finishing Materials
IMPORTANT FINISHING DETAIL NOTE:
Before placing unit into fi nal position - it is important to know the
total thickness / height of fi nished hearth (tile, carpet, etc.) The base
of the fi replace, 4 sided faceplate or mantel should be level or higher
than the fi nished hearth height.
Regency HZ33CE Gas Fireplace
3-1/2"
[89mm]
34-9/16"
878mm
Materials around unit.
3-1/2"
[89mm]
5-3/16"
[132mm]
WOOD STUD
1/2" DRYWALL
DO NOT EXTEND
DRYWALL ONTO METAL
SURFACE OF UNIT.
Non-combustible
Finishing Material
NON-COMBUSTIBLE FACING
FOR CLEAN LOOK
(ie. PAINTED FINISH)
1/2" DRYWALL
Non-combustible
Finishing Material
Note:
All non-combustible facing material should butt up cleanly
to the fl anges around the fi rebox opening.
Rough edges may be visible from an angle.
To maintain a clean fi nished edge - facing material edges
may be fi nished with a J-style trim or metal cornerbead (both
materials available at your local building or hardware store).
IMPORTANT: Materials used must be NON-COMBUSTIBLE.
INSTALLATION
Combustible
Material
Non-combustible Material (3-1/2" x 34-9/16")
Nailing Strip -flush with unit
Ensure finished
material is
brought to lip
Combustible
Material
No Combustible
Materials in this Area
J Style trim or metal
corner bead may be
used to finish edges
29-7/16"
747mm
Trim materials