CONVERSION KIT# 434-972 FROM NG TO LP
For HZ33CE using SIT 886 NOVA Gas Valve
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Each Kit contains one LPG
Conversion Kit # 434-972
LPG Conversion Kit Contains:
Qty. Part #
Description
1
904-241
Burner Orifi ce #56
1
918-590
Decal "Converted to
LPG"
1
908-528
Red "LPG" label
1
904-529
5/32" Allen Key
1
910-101
LPG Injector
(Pilot Orifi ce)
1
911-009
Hi/Lo Conversion LP
1
919-126
Instruction Sheet
Installation of the LPG
Conversion Kit:
1.
Shut off the gas supply
2. a) Remove the glass door.
b) Remove the Glass Crystals or
Ceramic Stones. Also remove
Inner Panels - if installed.
c) Remove the six (6) screws in locations
shown below to remove burner tray.
Diagram 1
Regency HZ33CE Gas Fireplace
3.
Remove 2 screws in location shown in
below - slide burner to the right then lift
out. (See Diagram 2)
Diagram 2
4. Pull off the pilot cap to expose the pilot
orifi ce.
Diagram 3
5.
Unscrew the pilot orifi ce with the Allen
key and replace with the LPG pilot
orifi ce in the kit and replace pilot cap.
Diagram 4
INSTALLATION
6.
Remove burner orifi ce with a 1/2"
wrench and discard. Use another
wrench to hold on to the elbow below
the orifi ce.
Diagram 5
Burner Orifi ce
7.
Install the new burner orifi ce stamped
#56.
8.
Remove regulator and discard. Install Hi/
Lo pressure regulator onto the valve with
2 screws as shown below.
Diagram 6
9. Attach the label "This unit has been
converted to LPG" near or on top of the
serial # decal
10. Replace yellow "NG" label with red
"LPG" label
11. Reverse steps 2 - 1.
12. Check for gas leaks.
13. Check inlet and outlet pressures.
14. Check operation of fl ame control.
Installer Notice:
These instructions must be left
with the appliance
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hz33ce-lp

Table of Contents