Optional Fan Wiring Diagram; Installing The Optional Fan (Installed Unit) - Regency HZ33CE-NG Owners & Installation Manual

Hide thumbs Also See for HZ33CE-NG:
Table of Contents

Advertisement

Lockwasher
Star washer
(for mobile home)
Nut
Fan
ground wire

INSTALLING THE OPTIONAL FAN (INSTALLED UNIT)

120 Volt AC power is needed for the fan switch and blower. The fan can be
hard wired if desired. The grounded duplex receptacle should be installed
into the supplied receptacle box by a qualifi ed electrician. The neutral (wider)
slot of the polarized receptacle should be at the top.
Unit must be grounded at all times. Do not cut the ground terminal off
under any circumstances.
1. Shut the power off.
2. Remove Flush door (See instructions in this Manual).
3. Remove inner panels (See instructions in this Manual).
4. Remove glass crystals or ceramic stones.
5. Remove the base tray by removing 6 screws in the locations shown
below.
Diagram 1: Remove the 6 screws and then lift
out the base tray
Regency HZ33CE Gas Fireplace

OPTIONAL FAN WIRING DIAGRAM

#8 Ground Lug
120V AC
60 Hz
Ground
Neutral
Green
Live
Ground
ON
OFF
Rotary Speed
Control
NOTE: Wiring schematics for P36E-4 (120 Volts),
plug-in fan circuit with speed control switch on wall.
6. Remove 2 screws in location shown below - slide burner to the right
then lift out. (See Diagram 2.
INSTALLATION
Fan
Black
Red
Red
Fan Thermodisc
(normally open)
Diagram 2
39