This is a copy of the label that accompanies each HZ33CE Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.
®
NOTE: Regency
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Listed:
Certified for/Certifi e pour:
Tested to:
ANSI Z21.88-2009/CSA 2.33-2009
4001172
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
NATURAL GAS:
Model HZ33CE-NG
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
PROPANE:
Model
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details.
Fan (Part # 432-917)
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard.
Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les
règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters.
For use with glass doors certified with the appliance only
VENTED GAS FIREPLACE HEATER -
FOYER AU GAZ À ÉVACUATION -
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas fi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible con-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
Regency HZ33CE Gas Fireplace

COPY OF SAFETY DECAL

VENTED GAS FIREPLACE HEATER
é
CANADA and U.S.A.
CAN/CGA-2.17-M91(R2009)
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
5"
WC
(1.25 kPa)
Pression a la tubulure d' chappement lev e
3.5"
WC
(0.87 kPa)
Pression a la tubulure d' chappement basse
1.6"
WC
(0.39 kPa)
Grandeur de l'injecteur
# 47
DMS
D bit Califorique minimum selon
é
12,000 Btu/h (3.51 kW)
D bit Caliorfique maximum selon
é
17,000 Btu/h (4.98 kW)
l'altitude
0-4500 ft/pi
(0-1372 m)
HZ33CE
-LP
APPAREIL FONCTIONNANT AU PROPANE
CONCU POUR ETRE POELE:
Pression d'allimentation minimum
11"
WC
(2.73 kPa)
Pression a la tubulure d' chappement lev e
10"
WC
(2.49 kPa)
Pression a la tubulure d' chappement basse
6.4"
WC
(1.59 kPa)
# 56
DMS
Grandeur de l'injecteur
12,500 Btu/h (3.66 kW)
D bit Califorique minimum selon
é
15,000 Btu/h (4.39 kW)
D bit Caliorfique maximum selon
é
0-4500 ft/pi
(0-1372 m)
l'altitude
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil
NOT FOR USE WITH SOLID FUELS.
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
Duplicate S/N
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
Minimum Clearances to Combustibles
Degagement Minimum De Materiaux Combustibles
Modéle
HZ33CE
-NG
Ceiling
é
é
é
é
A
Modéle
HZ33CE
-LP
é
é
é
C
é
DOOR SEAL: Please check that
the door is properly sealed
(See Instruction Manual for Detailed Instructions)
Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.
Made in Canada / Fabrique au Canada

SAFETY LABEL

406
Serial No./ No de serie
406
0" Clearance to
combustibles from:
Sides, bottom and rear of unit
*Top - 3-1/2" (89mm) non-combustible
material required above unit.
Wall
Ceiling Clearances from
Top Opening of Unit:
(A) 30" (762mm)
Side Wall Clearance from
Side Opening of Unit:
B) 9"(229mm)
Floor Clearance:
C) 0"
Floor
Alcove Clearances
D)
Min. Width 84" (1219mm)
E)
Max. Depth 36" (914mm)
FPI Fireplace Products International Ltd.
Delta, BC, Canada
919-119