Sign In
Upload
Manuals
Brands
MRU Manuals
Measuring Instruments
SWG100 BIOEX
MRU SWG100 BIOEX Biogas Analyzer Manuals
Manuals and User Guides for MRU SWG100 BIOEX Biogas Analyzer. We have
3
MRU SWG100 BIOEX Biogas Analyzer manuals available for free PDF download: User Manual
mru SWG100 BIOEX User Manual (150 pages)
Brand:
mru
| Category:
Measuring Instruments
| Size: 5 MB
Table of Contents
Table of Contents
3
General Information
7
Weather and Environmental Conditions
7
Installation Instructions
7
General Important Instructions for the Plant Operator
7
Important Information about the User's Operation Manual
8
General Warnings
9
Safety Information
9
Packing
11
Return of Hazardous Waste
11
Return of Analyzer
11
MRU Guarantee Conditions
12
Important Notes: Operating an ATEX Analyser
13
Weekly Maintenance Intervals
13
Correct Commissioning of the Unit
13
Check / Replace Peristaltic Pump Hoses
14
Check Material Resistance
14
Free Measurement before Opening the Unit
14
Analyzer Description
15
Intended Use
15
Principle of Operation
16
Marking and Range of Application
18
Possible Applications and Analyzer Options
18
Features
18
Overview of the SWG-100BIO Ex
19
Scope of Supply and Delivery
19
Material Required for the Installation (Not Scope of Supply)
19
SD-Card Content
19
Dimensions and Views of the Analyser
20
Position of the Gas in and Outlets
21
Operating Unit: Display and Keypad
22
Measurement Menu
24
Explosion Protection Systems of SWG100BIO-EX
25
Electrical Components
25
IP 65 Cabinet
25
CH4 Measurement of Inside Cabinet
26
Remote Power Supply Box
29
Sample Gas Measurement
31
Cycle Configuration
31
H2Slow Sensor Protection (Optional)
36
Analyzer Mounting and Installation
38
Content of Your Order
38
Installation Rules to Guarantee Explosion Protection
38
Prerequisites for Installation
38
Steps for the Mechanical Mounting and Installation
39
Mounting the Analyser on a Wall or Steel Rack
40
Correct Tubing of the SWG100BIO-Ex
42
Flow Restrictor Orifice (#65114)
43
Installation of the Power Supply
45
Installation of the External Switch-Off Circuit
46
Connection of the I/O Module
49
Power up and Commissioning the Analyser
51
Power up the Analyser
52
Check Country and Language
53
Check Date and Time of the Instrument
53
Configure Sampling Points
53
Configuration of the Alarm Relays
54
Configuration of the Modbus
56
Dilution-Unit
58
Correct Installation of the SWG100
58
Tubing of All Sample Gas Inlets
58
Installation of the Calibration Gas Cylinder
58
Fine Calibration of the Dilution-Unit
59
Software-Settings
61
Setting the Dilution Cycle
61
Binding to a Process Control System: I/O Modules
63
Position of the IO Module Inside the Analyzer
63
Pin Assignment
64
Analyser States
82
Configuration of the External Control (Option: IO Module)
82
Configuration of the External Control (Option: IO Module)
89
Operating the Analyser
93
General Process of the Measurement Cycle
93
Power-On of Analyser
94
Self-Test
94
Main Menu Measurement
95
Data Storage
97
Extra Menu: Overview
100
Power-Down of Analyzer
107
Backup/Restore All Individual User-Settings
107
Default Configuration
108
Update the Firmware
111
Service and Maintenance
114
Preparing and Information about the Maintenance
114
Regular Maintenance Works by the Operator
114
Position and Overview of the Service-Parts
116
Cleaning the Surface of SWG100BIO-Ex
121
Maintenance of the Switch-Off Relay (K2) and the Solenoid Valve for CH4 Supervision
121
Exchange of Electrochemical Sensors
123
Adjustment of the NDIR-Bench
126
Troubleshooting
133
Technical Specification
134
General Information
138
Special Informationen about the Modbus Slave Function
138
Special Informationen about the Profibus Slave Function
139
Defined Registers to be Read by the Master
139
Analyser Status (Address 0 and some Mirror Addresses)
143
Analyser System Alarm (Address 2 and some Mirror Addresses)
144
Appendix
145
Spare Parts List
145
Declaration of Conformity
147
Advertisement
mru SWG100 BIOEX User Manual (158 pages)
Brand:
mru
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Table of Contents
3
Information for Product and Safety
6
Safety Manual
6
Safety Precautions
6
Weather and Environmental Conditions
8
General Important Instructions for the Plant Operator
9
Packing
9
Return of Hazardous Waste
9
Return of Analyzer
9
MRU Warranty Conditions
9
Analyser Description
11
Intended Use
11
Principle of Operation
11
Physical Characteristic of the Gas Analyzer
13
Scope of Supply / Mounting Positions
15
Installation Manual
17
Overview
17
Select Measurement Point
18
Installation of the Mounting Flange
20
Installation of the Analyzer
22
Connection of Main Power Supply
23
I/O Modules: Installation and Setting
24
Installation: Sample Gas Outlet (VENT)
26
Installation: Calibration Gas / Zero Gas and Condensate Outlet
27
Installation of the Sampling Line and Probe
28
Operation of the Analyzer (HMI)
33
Display and Keypad
33
Analyzer Commissioning Manual
34
Check Country and Language
34
Check Date and Time of the Instrument
34
Configuration of the Alarm Relays
35
Configuration of the Modbus
37
Binding to a Process Control System: I/O Modules
39
Position of the IO Module Inside the Analyzer
39
Pin Assignment
40
Analog Outputs 4-20 Ma
42
Alarm Outputs
48
Analog Inputs (4-20 Ma)
53
Configuration of the External Control (Option: IO Module)
58
Mounting and Installation of the Gas Cylinders for the Auto Calibration Function
65
Cycle Configuration
68
Administrator PIN Code
75
Power-On of Analyser
75
Operating the Analyser
76
General Process of the Measurement Cycle
76
Data Storage Menu
79
Extra Menu: Overview
83
Update the Firmware
93
Service and Maintenance
96
Preparing and Information about the Maintenance
96
Regular Maintenance Works by the Operator
96
Description of the Analyser
97
Exchange of Electrochemical Sensors
102
Maintenance: HD-Probe with Back Purge Function
104
Positions of the Components
105
Preparations
106
Maintenance: Filter Holder
107
Exchange the Seals
110
Technical Specification
112
Appendix
115
Specification Modbus Via RS485 Specification
115
Analyser Status (Address 0 and some Mirror Addresses)
119
Analyser System Alarm (Address 2 and some Mirror Addresses)
119
Heated Sampling Line General Remarks
120
General Instructions for the Heated Sampling Lines
122
Purchase Options of the Analyser
126
Option: Electric Sample Gas Cooler
126
Option: Cabinet Heater
127
Option: O2 Paramagnetic Cell Measurement 0-25,00
128
Option: Multiple Sample Point Switching and Monitoring (Time Sharing)
129
Option: Extra IO Module with 4 Channel 4-20 Ma
130
Option: CO Electrochemical Cell Measurement 0-2000Ppm/4000Ppm
131
Option: RS485 to Profi-Bus Converter
132
Option: RS485 to Ethernet Converter
133
Option: NDIR-Bench 334 MMM
134
Configuration of the Ethernetmodule
138
Declaration of Conformity
148
Charts
149
Gas Flow Chart
149
MRU SWG100 BIOEX User Manual (108 pages)
Brand:
MRU
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
3
General Information
6
Weather and Environmental Conditions
6
Installation Instructions
6
General Important Instructions for the Plant Operator
6
Important Information about the User's Operation Manual
7
General Warning
7
Safety Information
7
Packing
9
Return of Hazardous Waste
9
Return of Analyzer
9
MRU Guarantee Conditions
10
Analyzer Description
11
Intended Use
11
Principle of Operation
12
Marking and Range of Application
13
Possible Applications and Analyzer Options
13
Features
13
Overview of the SWG-100BIO Ex
14
Scope of Supply and Delivery
14
Material Required for the Installation (Not Scope of Supply)
14
Dimensions and Views of the Analyser
15
Position of the Gas in and Outlets
16
Operating Unit: Display and Keypad
17
Measurement Menu
19
Explosion Protection Systems of SWG100BIO-EX
20
Electrical Components
20
IP 65 Cabinet
20
CH Measurement of Inside Cabinet
21
Remote Power Supply Box
24
Sample Gas Measurement
27
Cycle Configuration
27
H2Slow Sensor Protection (Optional)
32
Analyzer Mounting and Installation
34
Content of Your Order
34
Installation Rules to Guarantee Explosion Protection
34
Prerequisites for Installation
34
Steps for the Mechanical Mounting and Installation
35
Mounting the Analyser on a Wall or Steel Rack
36
Correct Tubing of the SWG100BIO-Ex
37
Flow Restrictor Orifice (#65114)
38
Installation of the Power Supply
40
Installation of the External Switch-Off Circuit
41
Connection of the I/O Module
43
Power up and Commissioning the Analyser
45
Power up the Analyser
46
Check Country and Language
47
Check Date and Time of the Instrument
47
Configure Sampling Points
47
Configuration of the Alarm Relays
48
Configuration of the Modbus
50
Configuration of the External Control (Option: IO Module)
52
Configuration of the Analog Outputs at the I/O Module
56
Configure Alarm Output of I/O Module
57
Configure the AUX-Input on Software-Side
59
Operating the Analyser
60
Administrator PIN Code
60
Power-On of Analyser
60
Self-Test
60
Main Menu Measurement
61
Data Storage
63
Power-Down of Analyzer
64
Backup/Restore All Individual User-Settings
65
Default Configuration
65
Update the Firmware
67
Service and Maintenance
70
Preparing and Information about the Maintenance
70
Regular Maintenance Works by the Operator
70
Position and Overview of the Service-Parts
71
Cleaning the Surface of SWG100BIO-Ex
77
Maintenance of the Switch-Off Relay (K2) and the Solenoid Valve for CH4 Supervision
77
Exchange of Electrochemical Sensors
79
Analyzer Calibration
86
Troubleshooting
90
Technical Specification
91
Declaration of Conformity
95
Appendix
99
General Information
99
Special Informationen about the Modbus Slave Function
99
Special Informationen about the Profibus Slave Function
100
Defined Registers to be Read by the Master
101
Analyser Status (Address 0 and some Mirror Addresses)
104
Analyser System Alarm (Address 2 and some Mirror Addresses)
105
Spare Parts List
106
Advertisement
Advertisement
Related Products
MRU SWG100 BIOGAS
mru SWG100 CEM
mru SWG 100 biogas
mru SWG 100
mru SWG 100 SYNGAS
mru AIR fair SWG 100-BIO
mru SWG 100 SYNGAS - Ex
mru SYNGAS VARIOluxx
mru 410074US
mru 410075US2
MRU Categories
Measuring Instruments
Gas Detectors
Analytical Instruments
Security Sensors
Transmitter
More MRU Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL