Sign In
Upload
Manuals
Brands
GasTech Manuals
Gas Detectors
D-Guard2
GasTech D-Guard2 Manuals
Manuals and User Guides for GasTech D-Guard2. We have
2
GasTech D-Guard2 manuals available for free PDF download: Operator's Manual, Instruction Manual
GasTech D-Guard2 Operator's Manual (77 pages)
Digital Gas Detector with HART communications
Brand:
GasTech
| Category:
Gas Detectors
| Size: 6.51 MB
Table of Contents
Table of Contents
3
Manual Conventions
10
Warnings, Cautions and Notes
10
Limitations of Use
11
Product Safety Markings
12
Receiving and Storage
13
Receiving
13
Inspection
13
Storage
13
Gastech Contact Details
13
General Safety Practices
14
Relevant Personnel
14
Safety Communication
14
Safe Use of Equipment
14
Modifications to Equipment
14
Equipment Knowledge
14
Introduction
15
Purpose and Contents of this Manual
15
Product Identification and Type
15
Contents O F D-Guard 2 Package
16
Product Description
17
Product Function
17
Description of Operation
17
Installation
18
Installation Considerations
18
General Installation Practices
19
Detector Dimensions and Mounting Orientation
19
Mandatory Installation Considerations
20
Typical Barrier Connection
20
Intrinsically Safe Power Supply Connection
21
Maintaining Conditions of Certificate Conformity
22
Mounting the Enclosure
22
Mounting Surfaces and Environment
22
Detector Location
23
Electrical Connections
24
Field Terminal Access
24
Connection Details
25
Cable Entry and Connecting
25
Conductor Preparation
26
Installation Cable Choice
26
Cable Gland
27
Refitting the Detector Cover
27
Commissioning
28
Installation Verification
28
Performance Checks
29
Equipment Required for Performance Checks
29
Bump Test Conditions
30
Bump Test Procedure
30
Detector Operating System
32
Detector Power up
32
Home Screen Features
33
User Menu Status
33
Configuration and Calibration Menu Navigation System
34
Soft-Key Functions and Icons
34
Quick-Nav Function
35
Entering the Function Screens
35
Calibration
36
Why Calibrate
36
Preparing for Calibration
36
Zero Calibration
37
Auto-Zero Calibration
37
Saving the Zero Calibration Value
38
Manual Zero Calibration
38
Notes on Zero Calibration
38
Span Calibration
38
Auto Span Calibration
39
Saving Auto-Span Calibration Values
40
Manual Span Calibration
40
Performing a Manual Span Calibration
40
Saving Manual Span Calibrations
40
Isolating the Detector During Span Calibration
40
Current Loop Output Calibration
41
Setting the 4Ma Output Current
41
Setting the 20Ma Output Current
41
Dynamic Response Time Test Function
42
Running the DRT Checks
42
Detector Configuration
43
Sensor Configurations
43
Set Guard Band
43
Set Measurement Full-Scale
44
Detector Type
44
Setting Span Gas Concentration
45
Alarm Configuration
45
Making Alarm Configuration Changes (Alarm 1 Shown)
46
Alarm 1 Trip Level
46
Alarm 1 Hysteresis
46
Alarm 1 Trip Direction
47
Alarm 1 Normal State
47
Alarm 1 Latching
47
Alarm 2 Current Settings Screen
48
Digital Data Configuration
48
HART Setup Main Screen
48
Turning HART Communications on or off
48
HART Tag Data
49
HART Tag Data - Fixed Loop Mode
49
System Configuration
49
SYSTEM Setup Main Screen
49
Turning Detector Isolation on or off
49
Internal Temperature Sensor
50
Display Colour Invert
50
Sensor Temperature Compensation
50
Set Sensor Gain
50
Set Menu Passcode
51
Detector Messages and Warning States
51
Running Information and Fault Messages
51
HART Communications Active
51
Detector Fault - Detector Over-Range
51
Detector Fault - Detector Under-Range
51
Detector Fault - Upper Operating Temperature
52
Detector Fault - Lower Operating Temperature
52
Detector Fault - Sensor Presence Failure
52
Detector Fault - Low Sensor Sensitivity
52
Fault Log and Information Screens
52
Detector Fault Log
52
Detector Information Screen
52
Resetting the Detector Life Counter
52
Calibration Fault
53
Internal Parameter Storage Fault
53
Alarm Indication
53
Warn Alarm Indication
53
Danger Alarm Indication
53
Latched Alarm Indication
53
Resetting from Alarm State
53
Temporarily Silencing an Alarm
54
Clearing an Alarm State
54
Setting the Display Heading (Banner)
54
Connecting a Hart Field Communicator
55
Detector Maintenance
56
Visual Inspection
56
Hands-On (Detailed) Inspections
56
Gas Sensing Cell Replacement
57
Removing the Detector Main Board
57
Replacing the Sensor
57
General Detector Repair
58
Disposal of D-Guard 2 Components
58
18. Appendix A: Output Current Signal - Total Loop Resistance Vs Power Supply Voltage
59
Loop Resistance - Group I D-Guard
59
With Backlight Disabled - Loop at 22Ma
59
With Backlight Enabled - Loop at 22Ma
59
Loop Resistance - Group II D-Guard with Backlight Disabled - Loop at 22Ma
60
Loop Resistance - Group II D-Guard with Backlight Enabled - Loop at 22Ma
60
19. Appendix B:
61
Disabling the Display Backlight
61
20. Appendix C:
62
Chemical Compatibility
62
21. Appendix D:
63
Cross Sensitivity - Toxic Sensors
63
Cross Sensitivity - Infra-Red Sensors
63
22. Appendix E:
64
Environmental Effects on Detector Performance
64
Temperature
64
Pressure
64
Humidity
64
23. Appendix F:
65
System Menu Map
65
Performance Specifications
66
General Specifications
66
Methane Detector Specifications
66
Carbon Dioxide Detector Specifications
67
Electro-Chemical Detector Specifications
67
Mechanical & Environmental Specifications
67
Appendix H - Product Certificates
68
Iecex Product Certificate
68
Atex Product Certificate
72
Appendix I - Product Dimensions
76
Advertisement
GasTech D-Guard2 Instruction Manual (59 pages)
Brand:
GasTech
| Category:
Gas Detectors
| Size: 1.58 MB
Table of Contents
Introduction
2
Method of Operation
2
For Your Safety
2
Further Information
2
Table of Contents
3
List of Figures
5
Keywords and Symbols Used in this Manual
6
Intended Use
7
Safety Precautions
7
Models Covered by this Instruction Manual
7
What Is in the Box
8
Installation Information
9
D-Guard² Mechanical Installation
9
Electrical Installation
10
Response Test
11
Operation
12
Power up
13
Home Screen Features
14
Unlock the Menu Screen
14
Passcode Requested
15
Calibration
16
Access the Calibration Menu
16
Attach the Calibration Gas to the D-Guard²
17
Calibration Modes
18
Calibration Trend Bar
18
Auto Zero Calibration
19
Auto Span Calibration
20
Manual Zero Calibration
21
Manual Span Calibration
22
System Information
23
Status
24
Clear Latched Alarms
24
Sensor Settings
25
Access the Sensor Settings Menu
25
Set Detector Full Scale
26
Set Span Gas Concentration
27
Set Zero Gas Concentration
28
Set Suppression Band
29
Sensor Gain
30
Alarm Settings
31
Access the Alarm Settings Menu
31
Alarm Direction
32
Alarm Level
33
Alarm Relay State
34
Alarm Latch
35
Latched Alarm Examples
36
System Settings
37
Access the System Settings
37
Isolate
38
Set Passcode
39
Disable Passcode
40
Advanced Settings
41
Access the Advanced Settings Menu
41
System Calibration
42
4-20Ma Output Test
43
Relay Function Test
44
Reset Sensor Life
45
Sensor Presets
46
Error Codes
47
23 4-20Ma Output Fault Conditions
47
Specifications
48
Enclosure Specifications
48
Mechanical Specifications
50
General Specifications
51
Wiring Requirements
51
D-Guard² General Versions, Gas, Range, and Resolution
52
Warranty
53
Sensor Warranty Periods
53
Replacement Parts
54
Replacement Parts - Exploded View
54
Replacement Parts - List
55
PCB (Part Number 57-0028) Configuration Jumpers
56
Maintenance
57
Calibration Interval
57
Cleaning
57
Visual Inspection
57
Gastech Policy Statements
58
Advertisement
Related Products
GasTech D-Guard
GasTech D-Guard2S
GasTech D-GUARD2R
GasTech Cannonball 3
GasTech F-GUARD UVIR
GasTech F-Guard-IR3
GasTech F-Guard-IR3-H2
GasTech F-Guard-IR3-H2-HD
GasTech F-Guard-UV-IR-F-HD
GasTech F-Guard-UV-IR-HD
GasTech Categories
Gas Detectors
Security Sensors
Boiler
Docking Station
Portable Generator
More GasTech Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL