Sinclair ASGE-09A Service Manual page 129

Uni on/off serie outdoor units: asge-**a indoor units: ascu-**a, asdu-**a, asfu-**a
Table of Contents

Advertisement

Disassembly and Assembly of Compressor
Remark : Make sure there isn't any refrigerant in pipe system and the power supply is cut off before
removal of the compressor..
Step
1. Disassembly of power
supply wire
2. Disassembly of fixing
nuts on compressor
3. Disassembly of suction
and exhaustion pipe
Illustration
MAINTENANCE
Handling Instruction
Loose the fixing screws for
power supply wire.
Pull
away
the
power
supply wire.
Attention: During removal
of the power supply wire,
mark wire color with the
corresponding joint number
in case of wrong connection.
Disassemble fixing nuts on
compressor with wrench.
Heat
the
suction
and
exhaustion pipe with gas
welding before removing
compressor.
Provide
nitrogen
protection
during
gas
welding and the nitrogen
pressure
should
2
0.5±0.1kgf/cm
relative
pressure .
Please pay attention to
heating
in
case
that
surrounding
materials
should be burnt by high
temperature.
be
128