Sinclair ASDU-09A User Manual

Uni on/off series
Hide thumbs Also See for ASDU-09A:

Advertisement

Quick Links

USER'S MANUAL
UNI ON/OFF SERIES
ducted units
ASDU-09A, ASDU-12A, ASDU-18A, ASDU-24A
ASDU-36A, ASDU-42A, ASDU-48A, ASDU-60A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ASDU-09A and is the answer not in the manual?

Questions and answers

Summary of Contents for Sinclair ASDU-09A

  • Page 1 USER'S MANUAL UNI ON/OFF SERIES ducted units ASDU-09A, ASDU-12A, ASDU-18A, ASDU-24A ASDU-36A, ASDU-42A, ASDU-48A, ASDU-60A...
  • Page 2 Thanks for your selection of Sinclair Ducted Air-Conditioning Unit. Before use, please read this instruction manual carefully and keep it properly to ensure correct use of this machine.
  • Page 3: Table Of Contents

    Safety Considerations Wire controller (standard fitting) Turning On/Off Unit Component Description Temperature Setting Fan Control Sleep Function Setting Operating Mode Setting Timing Setting Operating Operating Energy Saving Setting Instructions Instructions for Line Display of Outdoor Ambient Temperature Controller Power-fail Memory Function Setting Debug Function Failure Display Operation of Remote Controller...
  • Page 4: Safety Considerations

    Safety Considerations Please read this manual carefully before use and operate correctly as instructed in the manual. 1. You are specially warned to note the two symbols below.: WARNING!:A symbol indicating that improper operation might cause human death or severe injury WARNING!:...
  • Page 5 Wire controller (standard fitting) Composition of wire controller Failure status display 1 Timing display Sleep st atus display Fan speed display (Auto, High speed, Medium Mode key speed, Low speed) Defros ting st atus display Se t temperature increase key Energy saving st atus display Se t temperature decr ease key Se t temperature display...
  • Page 6: Turning On/Off Unit

    Oper ating istructions of wire controller Turning ON/OFF unit Pr ess t he ON/OFF ke y, then the unit shall star t up. Pr ess t he ON/OFF key again, then the unit shall shut off. Fan contr ol (the figur es show the r elevant display ar eas) If the fan control key is prssed consecutively, the fan speed shall changes as per t he following sequence: Low speed...
  • Page 7: Sleep Function Setting

    Sleep function setting When the controller functions under cooling or dehumidifying mode and if the unit runs for one hour after the sleep key is pressed, the set tem- perature shall increase by 1, and the set temperature shall increase by another 1 after 2 hours and the unit shall run as per the increased set temperature.
  • Page 8 Timer Setting When the unit is shut off, timing start can be set; After the unit is started up, timing shutoff can be set. After the "TIMER"key is pressed, the unit enters the timing set status and the word "TIMER" flashes on the display.
  • Page 9 The indoor room temperature is measured at the wire controller when the mode is 'heating' or 'auto'. At other modes is measure at the air intake(Now the OUT ENV area displaus 03) ,The default is 03.
  • Page 10: Failure Display

    Failure Display When there is failure in the unit operation, “ERROR” will flash on the LCD of the wire controller and the code of fai- lure will also be displayed. When there are multiple failures at the same time, the codes of failures will be displayed one after one on the wire controller.
  • Page 11: Operation Of Remote Controller

    Operation of Remote Controller Precautions: • Ensure there is no obstacle between the remote controller and the signal recei- ving window of the air conditioner. • The distance able to receive the signal of the remote controller can be as far as 8 meters.
  • Page 12 Cooling Mode Operation Connect the unit to power supply. Press the “ON/OFF”key. Press the “MODE” key to select “Cooling” mode. Use the “Temperature” key to adjust the set temperature for the room. a) After the unit is connected to power supply, the air conditioning unit shall enter the operating status if you press the ON/OFF key b) Press the mode key and select the...
  • Page 13 DRY (Dehumidifying) Mode Operations Connect the unit to power supply. Press the “ON/OFF” key. Press the “MODE” key to select “DRY (Dehumidifying)” mode. Use the “Temperature” key to adjust the set tempe- rature for the room. a) After the unit is connected to power supply, the air conditioning unit shall enter the operating status if you press the ON/OFF key...
  • Page 14 Loading Batteries Into Remote Controller • After batteries are installed, the display shall display icons and letter codes of all functions. • The life of batteries is about 1 year. • Do not mix new and old batteries or mix different types of batteries in usage •...
  • Page 15: Weekly Timer

    U nit Function • 7DP - Seven days programmer (Accessory not supplied) Centralized Control and Week Timer trol and the week timing functions. the lower unit. The weekly timing fun- Functions: The centralized control- Up to 16 sets of units can be control- ction is able to realized four timing ler and the weekly timer are integra- led simultaneously by the centralized...
  • Page 16 Note: 1. For upper unit checks 16 lower units consecutively, there will be no more than 16 seconds delay when setting works till unit responds. Please let us know your requirement before your placing the order, for this WEEKLY TIMER will only be prepared when customer orders (communication joint with WEEKLY TIMER on manual control had been prepared).
  • Page 17 Wire controller (with week timer functions) Composition of wire controller(Accessory not supplied) Sleep st atus display 1 Timing display Mode key Fan speed display (Auto, High speed, Medium Se t temperature incr ease key speed, Low speed) Defros ting st atus display Se t temperature decr ease key Energy saving st atus display Fan speed key (fresh air setting)
  • Page 18 • Wire controller with week timer function,No.1-No17 is the same as front   • instructions of No18,No.19: Timer setting (Fig. 15, 16, 17)   The timer function of this display board is invalid when connect with the timer   SEG of the last week, the display board will be controlled by the week timer.
  • Page 19 If enter into timer setting, by pressing “Mode” button to select the setting item: Day (Monday to Sunday), Segment (1-4), Timer (timer on or timer off), the ON Minutes and Hours of the time; By DAY              SEG pressing “▲”、“▼” buttons to adjust the setting, then press the Timer button to confirm, and press the Timer button once more to cancel the setting;...
  • Page 20 If enter into “Cancel Timer”, by pressing   “▲”、“ ” buttons to select Week, then   press the “Timer” button to confirm, at this   time, “dd” will display; or press “Timer” DAY   button to cancel the selected day, at this  ...
  • Page 21 Unit Function Setting of Indoor Room Sensor and Checking of Outdoor Ambient Temperature 1. Setting of Double Indoor Room Sensors This series of ducted air-conditioning unit has two indoor room sensors. One is located at the air intake of the indoor unit and the other one is located inside the wire controller. User can select one from the two indoor room sensors on the basis of the engineering requirement.
  • Page 22: Fresh Air

    Indoor Side the healthy filter block Air Valve Fig.24 4. The head of delivery of the condensate drainage pump can reach 1.1m, so that the engineering installation is very convenient and prompt. ASDU-09A ASDU-12A Pump ASDU-18A ASDU-24A Pump ASDU-36A...
  • Page 23 G a s P ip e L iq u id P ip e A ir In ta ke D ra in a g e P ip e A ir In ta k e Be suit for ASDU-09A ASDU-12A ASDU-18A Fig.26 Air Intake Gas Pipe...
  • Page 24 Profile Dimensions of Indoor Unit   Instructions of Unit Installation Profile Dimensions of Indoor Unit Model ASDU-09A 3/8〞 〞 ф 20×1.5 1/2〞 ASDU-12A ASDU-18A 1/2〞 ф 30×1.5 1012 1/4〞 ф 20×1.5 ASDU-24A 1159 1101 1270 1002 3/8〞 5/8〞 ASDU-36A ASDU-42A...
  • Page 25: Installation Of Outdoor Unit

    Instructions of Unit Installation Profile Dimensions of Outdoor Unit 1. Profile Dimensions of Outdoor Unit Unit:mm Model ASGE -09A ASGE-42A ASGE-12A ASGE-36A ASGE-24A ASGE-48A Item ASGE-18A 1018 1018 1250 Fig.31 Unit Installation Instructions Precautions on Installation of Outdoor Unit To ensure the unit in proper function, selection of installation location must be in accordance with following principles: (1) Outdoor shall be...
  • Page 26 Unit Installation Instructions Installation of Indoor Unit (4) Avoid direct sunshine over the unit. It is better to set up a sun shield as the protection. (5) Place of installation must be able to drain the rainwater and defrosting water. (6) Place of installation must ensure the machine will not be buried under snow or subject to the influence of rubbish or oil fog.
  • Page 27 Unit Installation Instructions Inspection of Level of Indoor Unit, Fabrication of Backwater Elbow Precautions for unfavorable installation: 1. The preparation of all pipes (connecting pipes and drainage pipes) and cables (connecting lines of wire controller, indoor unit and outdoor unit) must be ready before the installation, so as to achieve smooth installation.
  • Page 28 Unit Installation Instructions Installation of Drainage Pipeline Cautions: The air supply pipe, the air intake pipe and the fresh air pipe must be covered with a layer of thermal insulation, so as to avoid thermal leakage and condensation. Firstly apply liquid nail on the pipes, then attach the thermal insulation cotton with a layer of tinfoil.
  • Page 29 Refrigerant to be Length Indoor Unit Filled (For Extra Liquid Gas Pipe Model and Outdoor Length of Pipe) Pipe Unit m ASDU-09A ASGE-09A 30g/m ASDU-12A ASGE-12A ASDU-18A ASGE-18A ASDU-24A ASGE-24A 60g/m ASDU-36A ASGE-36A ASDU-42A ASGE-42A 120g/m ASDU-48A ASGE-48A ASDU-60A ASGE-60A Note:...
  • Page 30 Instructions of Unit Installation Connection of Pipelines Connection of Pipeline 1. Align the flared end of the copper pipe with the center of the thread joint. Manually tighten the flared end nut. 2. Use torque spanner to tighten the flared end nut until the spanner clatters (Figure 38). One-Way Valve Gas Valve Liquid Valve...
  • Page 31: Installation Of Connecting Pipe

    Instructions of Unit Installation Installation of Connecting Pipe 10. If conditions allow, use a vacuum pump to remove air out from the valve. Refer to Figure 40 Pressure Gage Pressure Gage “HI” Knob “LO” Knob Liq id Valve Vacuum Pump Connecting Hose Gas Valve Fig.40...
  • Page 32: Position And Method Of Installing Wire Controller

    Instructions of Unit Installation Installation of Connecting Pipe (2) Use thermal insulation tape to wrap the pipes from the bottom of the outdoor unit until the upper end of the pipe where the pipe enters the wall. When wrapping thermal insulation tape, the later circle of tape must cover half of the front circle of tape (Refer to Figure 42).
  • Page 33 Instructions of Unit Installation Installation of Wire Controller Electric box cover sketch map for indoor unit communication wire Wire clamp Cable-cross loop Control wire Communication wire metallic pipe metallic pipe Figure 43 Surface Figure 44 Concealed Figure 45 Schematic Diagram of Installation Mounting of Cable mounting of Cable Name...
  • Page 34 Instructions of Unit Installation Electrical Installation Caution: Before installing the electrical equipment, please pay attention to the following matters which have been specially pointed out by our designers: (1) Check to see if the power supply used conforms to the rated power supply specified on the nameplate.
  • Page 35: Electrical Installation

    Instructions of Unit Installation Electrical Installation (4 ) Use cable fastener to bundle and fix the cable. 2。 Air-conditioning unit with 3-phase power supply Caution: 1 Remove the front-side panel of the outdoor unit. Take great care when carrying out the following 2 Attach rubber ring to the cable-cross hole of the connections, so as to avoid malfunction of the outdoor unit.
  • Page 36: Connection Of Cables

    The section area of cables selected by users must not be smaller than the specifications shown diagram.the signal wire between indoor and outdoor unit shall be installed in the shielded bushing Schematic Diagram of Unit Line Connection: ASGE-09A ASDU-09A ASDU-12A ASGE-12A ASDU-18A...
  • Page 37: Troubleshooting And Maintenance

    Note: After carrying out the check of the above items and taking relevant measures to solve the problems found but the air-conditioning unit still does not function well, please stop the operation of the unit immediately and contact the local service agency designated by Sinclair. Only ask professional serviceman to check and repair the unit.
  • Page 38 Instructions of Unit Installation Troubleshooting and Maintenance 4) Take care when cleaning the air-conditioning unit. Use a steady stepping stand. 2. Maintenance at the Beginning of Operating Season Check the air inlet and outlet of the indoor and outdoor units to confirm there is no blockage. Check to see if the grounding wire is in good condition;(Operating by the professional) Check to see if the line connection is in good condition;(Operating by the professional) Check if there is any word displaying on the LCD of the wire controller after connecting the unit...
  • Page 39: Appendix

    Appendix: Air conditioner nominal working condition and working range: Indoor side Outdoor side Test condition DB(℃) WB(℃) DB(℃) WB(℃) Nominal cooling Nominal heating ―― Rated cooling Low temp. cooling 18 ―― Rated heating ―― Low temp. heating ―― -7 -8 Note: 1.
  • Page 40: Environmental Information

    ENVIRONMENTAL INFORMATION This unit contains fluorinated gases with greenhouse effect covered by the Kyoto Protocol. Maintenance and disposal must be carried out by qualified persons only. Refrigerant gas R410A, GWP = 1730 EXTRA REFRIGERANT CHARGE Pursuant to Regulation EC 842/2006 on certain fluorinated greenhouse gases, in case of extra refrigerant charge, it is compulsory to: Fill in the label accompanying the unit inserting the factory quantity of refrigerant charge (see the technical label), the extra refrigerant charge and the total charge.
  • Page 41 This product must not be disposed together with the domestic waste. This product has to be disposed at an authorized place for recycling of electrical and electronic appliances. 66175219...

Table of Contents