  • Page 1 ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ Sinclair ASD-36BI/ASGE-36BI-3...
  • Page 4 To Users Thank you for selecting S i n c l a i r ’s product. Please read this instruction manual carefully before installing and using the product, so as to master and correctly use the product. In order to guide you to correctly install and use our product and achieve expected operating effect, we hereby instruct as below: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of...
  • Page 5 If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. (10) SINCLAIR CORPORATION Ltd. assumes no responsibility for personal injury, property loss or equipment damage caused by improper installation and commissioning, unnecessary maintenance, or not following relevant national rules and regulations, industrial standards and requirements in this instruction manual.
  • Page 7: Table Of Contents

    Contents 1 Safety Notice (Please be sure to abide) ......1 2 Product Introduction ............. 5 2.1 Overall Layout ................5 2.2 Operating Range ..............5 2.3 Standard Accessories .............6 3 Controller ................7 5 Maintenance ..............22 5.1 Failures Not Caused by Faults of the AC ......22 5.2 Error Code ................
  • Page 8: Safety Notice (Please Be Sure To Abide)

    1 Safety Notice (Please be sure to abide) SPECIAL WARNING: Be sure to comply with national gas regulations. Do not pierce or burn. Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. Be aware that refrigerants may not contain an odor.
  • Page 9 Before installing the air conditioner, please read the instruction manual. Before repairing the air conditioner, please read the instruction manual. The figures in this manual may be different with the material objects, please refer to the material objects for reference. PROHIBITED (1) The air conditioner should be grounded to avoid electric shock.
  • Page 10 (6) Air conditioner should be stored with protective measures against mechanical damage caused by accident. (7) If the installation space for air conditioner pipe is too small, adopt a protective measure to prevent the pipe from physical damage. (8) During installation, use the specialized accessories and components, otherwise water leakage, electric shock or fire hazard may occur.
  • Page 11 (5) Please select the proper copper pipe according to the requirement for pipe thickness. (6) Indoor unit can only be installed indoors while outdoor unit can be installed either indoors or outdoors. Never install the air conditioner in the following places: a) Places with oil smoke or volatile liquid: plastic parts may deteriorate and fall off or even cause water leakage.
  • Page 13: Product Introduction

    2 Product Introduction 2.1 Overall Layout NOTICE: (1) The connection pipe, drain pipe, power cord, and duct for this unit should be prepared by the user. (2) The unit is standard equipped with rectangular duct. 2.2 Operating Range Cooling (DB) Heating (DB) Outdoor temperature -20℃〜48℃...
  • Page 14: Standard Accessories

    2.3 Standard Accessories Indoor Unit Accessories Name Appearance Q'ty Usage Wired To control the indoor unit Controller Nut with To fix the hook on the cabinet of Washer the unit. To be used together with the hanger bolt for installing the unit To be used together with the Washer hanger bolt for installing the unit...
  • Page 15 Buttons on remote controller ON/OFF button MODE button FAN button TURBO button ▲/ button button button T-ON / T-OFF button I FEEL button CLOCK button SLEEP button WiFi button button LIGHT button TEMP button Introduction for icons on display screen Set fan speed fan speed.
  • Page 16 Introduction for buttons on remote controller Note: ● This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
  • Page 17 Introduction for buttons on remote controller Note: ● For preventing cold air, after starting up heating mode, indoor unit will delay 1~5 minutes to blow air (actual delay time is depend on indoor ambient temperature). ● Set temperature range from remote controller: 16~30℃ (61-86°F); Fan speed: auto, low speed, low-medium speed,medium speed, medium-high speed,high speed.
  • Page 19 Introduction for buttons on remote controller ● When setting T-ON, T-OFF or CLOCK, press "▲" or " " button to adjust time. (Refer to CLOCK, T-ON, T-OFF buttons) When setting T-ON, T-OFF or CLOCK press "▲" or " " button to adjust time. (Refer to CLOCK,T-ON, T-OFF buttons) button Press this button can select left &...
  • Page 20 Introduction for buttons on remote controller T-ON / T-OFF button ● T-ON button "T-ON" button can set the time for timer on. After pressing this button, " " icon disappears and the word "ON" on remote controller blinks. Press "▲" or "...
  • Page 21 Introduction for buttons on remote controller CLOCK button Press this button to set clock time. " " icon on remote controller will blink. Press "▲" or " " button within 5s to set clock time. Each pressing of "▲" or " "...
  • Page 22 Introduction for buttons on remote controller LIGHT button Press this button to turn off display light on indoor unit. " " icon on remote controller disappears. Press this button again to turn on display light. " " icon is displayed. TEMP button By pressing this button, you can see indoor set temperature, indoor ambient temp- erature or outdoor ambient temperature on indoor unit’s display.
  • Page 23 Function introduction for combination buttons Energy-saving function Under cooling mode, press "TEMP" and " CLOCK" buttons simultaneously to start up or turn off energy-saving function. When energy-saving function is started up, "SE" will be shown on remote controller, and air conditioner will adjust the set temperature automatically according to ex-factory setting to reach to the best energy-saving effect.
  • Page 25 Operation guide After putting through the power, press "ON/OFF" button on remote controller to turn on the air conditioner. Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN, HEAT. Press "▲" or " " button to set your required temperature. (Temperature can’t be adjusted under auto mode).
  • Page 26: Maintenance

    5 Maintenance 5.1 Failures Not Caused by Faults of the AC (1) If your air conditioner fails to function normally, please first check the following items before maintenance: Problem Cause Corrective measure If you turn off the unit and then immediately turn it on, in order to protect the compressor and Please wait for a while.
  • Page 27 (2) The following situations are not operation failures. Problem Time of occurrence Cause If the unit is running under Mist comes from the air high humidity, the wet air in During operation. conditioner. the room will be quickly cooled down. Defrosting process will System switches to generate some water,...
  • Page 28: Error Code

    ②. Do not repair the air conditioner by yourself. Improper maintenance will cause electric shock or fire hazard. Please contact Sinclair ’s authorized service center and send for professional service staff to repair. If the display panel or wired control displays an error code, please refer to the error code meaning stated in the following table.
  • Page 29 Error Number Error code Compressor overload protection Overload IPM protection DC fan error Driver out-of-step protection HC Pfc protection Startup failure Compressor phase-sequence protection Power protection IDU and ODU unmatched 4–way valve switch-over error Driver reset protection Over-current protection Master control and driver communication error Driver module sensor error Driver module high temperature protection Zero-crossing protection...
  • Page 31: Unit Maintenance

    5.3 Unit Maintenance Warning ①. Only professionals are allowed to carry on daily maintenance. ②. Before contacting any wire, make sure power is cut off. ③. Do not let any inflammable objects near the unit. ④. Do not use organic solvent to clean the air conditioner. ⑤.
  • Page 32 “ON” status before 8h of operation, to preheat the crankcase of outdoor compressor; (6) Check if the installation of outdoor unit is firm, if not, please contact with Sinclair appointed maintenance center. 5.3.5 Maintenance at the End of the Using Season (1) Cut off the main power of air conditioner;...
  • Page 33: After-Sales Services

    5.3.6 Components Replacement Components are available in Sinclair agency or Sinclair distributors nearby. 5.4 After-sales Services Any quality or other issues encountered in the purchased air conditioner, please contact the local Sinclair after-sales service department.
  • Page 34 SINCLAIR CORPORATION Ltd. 1-4 Argyll St. London W1F 7LD Great Britain www.sinclair-world.com This product was manufactured in China (Made in China). REPRESENTATIVE SINCLAIR Global Group s.r.o. Purkynova 45 612 00 Brno Czech Republic TECHNICAL SUPPORT SINCLAIR Global Group s.r.o. Purkynova 45...
  • Page 35 СМОТРИТЕ ТАКЖЕ Кондиционеры сплит- Моноблочные Потолочные Мультисплит-системы системы кондиционеры вентиляторы Установка настенных Сервис Бытовые рекуператоры Очистители воздуха кондиционеров кондиционеров Аксессуары для Напольные вентиляторы Фреон Труба медная кондиционеров Кронштейны для кондиционеров...