9-2. F-Functions

" " designates Factory Settings.
F-00-X Weight Unit
f-00-01
f-00-02
F-01-X Operations
f-01-01
f-01-02
"f-01-03" is for factory use and should be "0".
f-01-04
USA Version ONLY
Weight Display when the scale is switched on.
See also setting "f-09-01=2".
0
kg (kilograms).
1
3 lb (pounds).
Unit Weight (when "lb" is selected).
0
3 lb as piece weight.
1
lb as 1,000 piece weight.
Operation Mode.
0
3 Normal Operation. All features and keys available.
Simplified Operation. The unit weight registration is by
1
sample only. All other keys are disabled.
"Add" Sample Request Override.
If the sample weight is too light and the scale asks to "Add"
more sample pieces, using this F-Function, the unit weight
can be entered without adding the requested sample pieces.
Or disable the "Add" Sample Request function.
"Add" sample request function is disabled. Light unit weight
0
can be accepted without "Add" more sample request.
The unit weight can be entered without requested "Add"
1
3
sample pieces (via the ENTER key).
The unit weight cannot be entered without requested "Add"
2
sample pieces (via the ENTER key).
Display ON Unit Weight – Reset or Last.
When the scale is switched on, the scale can be set to recall
the last unit weight used.
0
3 The unit weight is RESET (cleared) when display comes on.
1
The unit weight last used will be entered automatically.
31