Never touch the circuit board chips
or circuits. Static electricity will
damage the circuit board. When
handling the circuit board always
CAUTION
disconnect the 120 VAC power and
use a static discharge wrist band.
AUDIO ALERTS
If your lift does not operate, diagnose the
problem by listening to the beeps emitted:
A long beep when the control switch is
pressed indicates the lift is touching an
obstruction.
One beep per second for 30 seconds (after
a 30 second delay) indicates the lift has
been stopped off the charge station. It is
recommended that the lift be immediately
moved to a charge station (located either
end of the rail).
Two beeps every 60 seconds indicates a
major fault with the circuit board. Turn unit
off and back on to reset.
Three beeps every 60 seconds indicate a
major fault with the footrest sensor. Turn
unit off and back on to reset.
Seven beeps every 60 Seconds indicate a
major fault with the slow down switches.
Turn unit off and back on to reset.
Eight beeps every 60 seconds indicate a
major fault with the limit switch. Turn unit
off and back on to reset.
If your lift fails to reset, contact your dealer for
service.
NOTE: A fault is defined as major any time it requires
the unit to be turned off and back on to reset.