Problem Solver - Monogram ZV30 Owner's Manual

Stainless steel professional range hood
Table of Contents

Advertisement

The Problem Solver
Professional
Range Hood
Questions?
Use this
problem
solver!
PROBLEM
POSSIBLECAUSE
e
FAN AND LIGHTS DO
NOT OPERATE WHEN
THE SWITCHES ARE
TURNED ON
The hood was never electricallg connected bg the installer/
electrician/builder. Call the electrician/installer/builder
to
complete the the installation. This is not covered bg warrantg.
A fuse mag be blown or a circuit breaker tripped. Replace the fuse
or reset the circuit breaker.
THE BLOWER DOES
NOT WORK BUT THE
LIGHTS DO
THE BLOWER FAILS
TO EXHAUST THE
SMOKE/STEAM/
ODORS ADEQUATELY
The blower motor wire harness was not connected or was not
connected properlg bg the installer/electrician/builder
to its mating
connector located inside the hood on the top surface, to the left of
the blower assemblg.
1. Switch power off at service panel and lock the service disconnecting
means to prevent power from being switched on accidentallg. When
the service disconnecting means cannot be locked, securelg fasten a
prominent warning device, such as a tag, to the service panel.
2. Remove the filters and locate the blower wire harness connector.
Is it plugged into its mating connector?
3. If no, plug the blower motor connector into its mating connector on
the top of the hood. Switch the power back on. Check to see
if the fan now works.
4. If no, check the circuit breaker/fuse. If it is blown/tripped, replace/
reset it. Does the blower work now? If no, call GEfor service.
• Many factors could be the root cause for reduced air-flow.
1. Installation
could be the problem: Your hood was designed to
meet specific ducting requirements. If gour duct length exceeds
the manufacturer's requirements, hood performance will suffer.
Air-flow will also be reduced if the house duct work is too small
or there are too mang elbows in the sgstem. Contact gour installer
or builder.
2. Obstruction in duct work could be the problem: Make sure nothing is
blocking the vent (bird nests or kinks in the duct work).
3. Dumper blade mag not be opening. Make sure the tape is removed
from the damper blades and that it swings open freelg.
4. Dumper blade on Wall or Roof Cap mug not be opening. Contact
gour builder so theg can make sure the damper swings open freelg.
S. Dirty filters/baffles
- Make sure filters (and all hood surfaces) are
kept clean of grease and dirt.
6. Check to be sure the filter is clean: If replacing the filter does not
correct the problem, call for service.
7. Sufficient makeup (replacement} air is required for exhausting
appliances to operate to rating. Check with local building codes,
which mug require or stronglg advise the use of makeup air.
Visit GEAppliances.com for available makeup air solutions.