Problem Solver - Monogram ZV900 Owner's Manual

36" glass canopy chimney vent hood
Table of Contents

Advertisement

Questions?
PROBLEM
FAN AUTOMATICALLY
Use this
TURNS ON AND CAN
problem
NOT BE TURNED OFF
solver!
FAN DOES NOT
OPERATE WHEN
TURNED ON
FAN FAILS TO CIRCULATE
AIR OR MOVES AIR
SLOWER THAN NORMAL
FAN KEEPS GOING
OFF AND ON
LIGHT WILL NOT STAY
ON HIGH SETTING OR
"WRONG WATT BULB"
APPEARS IN THE DISPLAY
THE HOOD CONTROLS
OR DISPLAY ARE NOT
OPERATING CORRECTLY
SEQUENTIAL PRESSES
OF THE LIGHT OR FAN
BUTTONS WILL
SOMETIMES CHANGE
THE SETTING FROM THE
LOWEST SETTING–TO OFF–
TO THE HIGHEST SETTING,
OR FROM THE HIGHEST
SETTING–TO OFF–TO THE
LOWEST SETTING
WHEN PRESSING THE
POWER ON/OFF BUTTON
TO TURN ON THE LIGHT,
THE FAN COMES ON
INSTEAD
The Problem Solver
POSSIBLE CAUSE
• The Sensor feature will automatically turn the fan on at the
MED setting and the display will show AUTO MODE ON if cooking
temperatures become too hot. The fan will stay on for a minimum
of 3 minutes and will then turn off when temperatures cool to an
appropriate level.
• A fuse may be blown or a circuit breaker tripped. Replace fuse or
reset circuit breaker.
• The power disconnect switch inside the hood may be switched off.
Remove the metal grease filter and the charcoal filter (if present) and
flip the switch on.
• Check to be sure the metal grease filter and the charcoal filter
(if present) are clean. Clean the metal grease filter (see the Metal
grease filter section) and, if the hood is recirculated (not vented to the
outside), replace the charcoal filter (see the Charcoal filter section).
If cleaning and replacing the filters does not correct the problem,
call for service.
• The motor is probably overheating and turning itself off. This can
be harmful to the motor. Check to be sure the filter is clean. If off
and on cycling continues, call for service.
• Use 12 volt, 20 watt halogen bulbs with a G4 base and make sure
they are inserted securely. See the Light bulbs section.
• Disconnect power to the hood by removing the fuse or turning the
circuit breaker off in the home fuse box. Wait 30 seconds to allow the
hood controls to reset and then replace the fuse or move the circuit
breaker back on.
• It is normal for the light and fan buttons to cycle around through the
settings so that you can easily set the controls to the desired setting.
• For your convenience, it is normal for the lights and fan to remember
their last setting when you press the Power On/Off button. If you
want only the lights on, press the "FAN +" (or the "FAN –" ) button until
"Off" is in the display. When you power the hood up next time, only
the lights will function.
Glass Canopy Hood