1.10 Installation of Carriage Drive Wire
When the carriage drive wire is replaced, attach the new wire as shown:
Tension spring
Pulley
1.10.1 Wire tension adjustment
(1) For this model, it is unnecessary to adjust the carriage drive wire tension.
1.10.2 Adjustment of carriage 1 and carriage 2
(1) Remove the indicator unit.
(2) Loosen the 3 screws fixing carriage-1 (2
screws, front, rear, 1 screw each) and -2 (1
screw in front) to the wire.
(3) While pressing carriage-2 against the exit side
frame (both A & B), tighten the carriage-2 fix-
ing screws (front side).
(4) Also while pressing carriages 1 and 2 against
the exit side frame (C & D), tighten the car-
riage-1 fixing screws.
September 1997 © TOSHIBA CORP.
Scanning motor
Belt
Rear side view
1 - 49
Carriage drive wire
Carriage 1
Carriage 2
Wire winding pulley
Pulley
Exit side frame
Carriage 1
Exit side frame
D
Carriage 2
B
Exit side frame
Pulley
Exit side frame
C
A
2460 ADJUSTMENT