Toshiba 2460 Service Handbook page 20

Digital plain paper copier
Table of Contents

Advertisement

Code
Name
255 PFP loading status
256 LCF paper size
259 Acceptable copy mode for the coin
controller
300 Maximum multiple copying
351 Electronic counter
352 A3/LD double count
400 Thermistor status counter
401 Drum life counter
402 Power-on time counter
403 Fuser running counter
404 Developer material counter
405 Drum potential control
(Counter correction)
406 Pre-running starting time
407 Pre-running time
408 Pre-running time at the thick paper
410 Fuser temperature at copying
411 Fuser temperature at ready
412 Fuser temperature in the energy
saver mode
September 1997 © TOSHIBA CORP.
Mode
Initial
Allowance
value
ALL
0
0~4
0: Automatic
2: PFP has 2 cassettes 3: PFP has 3 cassettes
4: PFP is not loaded
ALL
EUR=0
0~2
0: A4
UC=1
1: LT
2: B5
ALL
0
0~2
0: Normal copying
1: Not accepts a large size paper copying
2: Not accepts a large size paper and a X-Y zoom copying
ALL
0
0~2
0: 999
1: 99
2: 9
ALL
0
0~999999
ALL
0
0~1
0: Single count
1: Double count
ALL
0
0~9
0: No error has occurred
1~9: Error has occurred
ALL
0
0~999999 (Counts up according to the drum rotation)
ALL
0
9 digit
Hour (5 digit), Minute (2 digit), Second (2 digit)
ALL
0
0~999999 Synchronizes with the total counter
(Double count at long size)
ALL
0
0~999999 Synchronizes with the total counter
(Double count at long size)
ALL
7
0~7
0 bit: Grid potential temperature correction
1 bit: Grid potential life correction
2 bit: Laser output drum life correction
ALL
0
0~7
0 = Not functional
1 = 30 sec, 2 = 35 sec, 3 = 40 sec, 4 = 45 sec,
5 = 50 sec, 6 = 55 sec, 7 = 60 sec
ALL
2
0~10
0 = Not functional
1 = 5 sec, 2 = 10 sec, 3 = 15 sec, 4 = 20 sec,
5 = 25 sec, 6 = 30 sec, 7 = 40 sec, 8 = 50 sec,
9 = 60 sec, 10 = 150 sec
ALL
10
0~15
0 = Not functional, 1~10 = Setting seconds
11 = 12 sec, 12 = 14 sec, 13 = 16 sec,
14 = 18 sec, 15 = 20 sec
ALL
10
4~13
4: 170°C, 5: 175°C, 6: 180°C, 7: 185°C,
8: 190°C, 9: 195°C, 10: 200°C, 11: 205°C,
12: 210°C, 13: 215°C
ALL
7
0~7
0: 170°C, 1: 175°C, 2: 180°C, 3:185°C,
4: 190°C, 5: 195°C, 6: 200°C,
7: Temp. control ON
ALL
4
0~5
0: OFF, 1: 120°C, 2: 130°C, 3: 140°C, 4: 150°C,
5: 160°C
1 - 17
Remarks
1: PFP has 1 cassette
2460 ADJUSTMENT