Motor control card A002 (A001 = MSF)

Connectors

A002 / X1 / KM
X1/1
Connection to A001, X9/4
X1/4
Connection to A001, X9/10
A001 / X1 / MSF
X1/1
Bus +50V
X1/3
Tacho +5V
X1/4
Bus GND
X1/5
Tacho GND
X1/6
Tacho Signal
A002/A001 / X2
X2
Connection to panel card
A002 / X4 / MF
X4/2
Start
X4/3
Motor+
X4/4
U-measurement
X4/6
Pot +5V
X4/8
Connection A001 X9/2
X4/11 WF-pot
X4/12 Valve
X4/14 GND
X4/15 Motor -
A001 / X4 / MSF
X4/1
Pot GND
X4/2
Start 2
X4/3
Motor +
X4/4
Pot 2
X4/5
Start 1
X4/6
Pot +5V
X4/7
ID Bus 2
X4/8
Bus Data
X4/9
General I/O
X4/10 Valve -
X4/11 Pot 1
X4/12 Valve +
X4/13 ID Bus 1
X4/14 GND
X4/15 Motor -