Open Burners ('F' - Flame Failure Option)
Lighting the Open Burners
Flame Failure Protection is incorporated for each burner by way of a thermo-electric system which
will shut off gas supply to that burner in the event that burner goes out, so that un-burnt gas is not
expelled.
a. Select burner required, depress and turn the gas control knob anti-clockwise to 'HIGH' position.
b. Hold gas control knob depressed and manually light main burner.
c. Release
gas control knob
d. Burner should stay alight - if not, repeat Steps (a. to (c. above.
e. To adjust the temperature required, depress and rotate gas control knob between 'HIGH' and
'LOW' positions.
Turning 'OFF' the Open Burners
a. When main burner is not required, depress and turn gas control knob clockwise back to 'OFF'
position. 'MAIN' burner will extinguish.
Open Burners ('PF' - Pilot and Flame Failure Option)
Lighting the Open Burners
These hobs are fitted with individual standing pilots for each open burner which allows main burners
to be turned 'ON' - 'OFF' without having to manually re-light burner each time that it is turned 'ON',
as burner will automatically light itself off the pilot burner.
Flame Failure Protection is incorporated for each burner by way of a thermo-electric system which
will shut off gas supply to that burner in the event that burner goes out, so that un-burnt gas is not
expelled.
a. Select burner required, depress and turn the gas control knob anti-clockwise to 'PILOT' position.
b. Hold gas control knob depressed and manually light pilot burner.
c. Release
gas control knob
d. Pilot burner should stay alight - if not, repeat Steps (b. to (c. above.
e. To select 'Full Flame', depress and rotate gas control knob anti-clockwise to first stop 'HIGH'
flame position.
f. To select 'Low Flame', depress and rotate gas control knob fully anti-clockwise to 'LOW' flame
position.
g. To adjust the temperature required, depress and rotate gas control knob between 'HIGH' and
'LOW' positions.
Turning 'OFF' the Open Burners / Pilots
a. To turn 'OFF' main burner, but keep pilot burner alight, rotate gas control knob to 'PILOT'
position. Main burner will extinguish and pilot will remain alight.
b. To turn 'OFF' the 'PILOT', depress and turn gas control knob clockwise back to 'OFF' position.
'PILOT' burner will extinguish.
after approximately 10-20 seconds after lighting burner.
after approximately 10-20 seconds after lighting pilot burner.
11