Open Burners - Waldorf RN8510GE Operation Manual

800 series gas ranges electric static/convection oven
Table of Contents

Advertisement

Open Burners

NOTE: Only cooking pans from size Ø 150mm to Ø 420mm are suitable fo use on these open
burners.
Flame Failure Option (F-Models)
Lighting the Open Burners
Flame Failure Protection is incorporated for each burner by way of a thermo-electric system which
will shut off the gas supply to that burner in the event that the burner goes out, so that un-burnt gas
is not expelled.
a. Select the burner required, depress and turn the corresponding gas control knob anti-clockwise to
the 'HIGH' position.
b. With the gas control knob depressed, manually light the burner.
c. Release
the gas control knob
d. The burner should stay alight - if not, repeat Steps (a to (c above.
e. To achieve simmer control, depress the gas control knob and rotate between the 'HIGH' and
'LOW' positions to achieve the temperature required.
Turning 'OFF' the Open Burners
a. When the main burner is not required, depress and turn the gas control knob clockwise back to
the 'OFF' position. The 'MAIN' burner will extinguish.
Pilot and Flame Failure Option (PF-Models)
Lighting the Open Burners
These hobs are fitted with individual standing pilots for each open burner which allows the main
burners to be turned 'ON' - 'OFF' without the need to manually re-light the burner each time that it is
turned 'ON', as the burner will automatically light itself off the pilot burner.
Flame Failure Protection is incorporated for each burner by way of a thermo-electric system which
will shut off the gas supply to that burner in the event that the burner goes out, so that un-burnt gas
is not expelled.
a. Select the burner required, depress and turn the corresponding gas control knob anti-clockwise to
the 'PILOT' position.
b. With the gas control knob depressed, manually light the pilot burner.
c. Release
the gas control knob
d. The pilot burner should stay alight - if not, repeat Steps (a to (c above.
e. 'Full Flame' can now be achieved by depressing and rotating the gas control knob anti-clockwise
to the first stop 'HIGH' flame position.
f. Low flame can be achieved by depressing the gas control knob and rotating fully anti-clockwise to
the 'LOW' flame position.
g. To achieve simmer control, depress the gas control knob and rotate between the 'HIGH' and
'LOW' positions to achieve the temperature required.
Turning 'OFF' the Open Burners / Pilots
a. To turn 'OFF' the main burner, but keep the pilot burner alight, rotate the gas control knob to the
'PILOT' position. The main burner will extinguish and the pilot will remain alight.
b. To turn 'OFF' the 'PILOT', depress and turn the gas control knob clockwise back to the 'OFF'
position. The 'PILOT' burner will extinguish.
after approximately 10-20 seconds after lighting the burner.
after approximately 10-20 seconds after lighting the pilot burner.