Approved Vent; Vent Installation - Travis Industries 21 TRV GSR2 Installation Manual

Hide thumbs Also See for 21 TRV GSR2:
Table of Contents

Advertisement

Approved Vent

Rear vent configurations use 8" diameter Simpson Dura-Vent Model Direct-Vent Pro (or GS)*.
Top vent configurations use 8" or 6-5/8" diameter Simpson Dura-Vent Direct-Vent Pro (or GS)*. If
using 6-5/8" diameter vent, attach the 8" to 6-5/8" reducer (Travis part # 98900165) to the fireplace.
* Other vent may be approved with this fireplace. Check with the vent manufacturer for details.
Always use the high-wind cap (or high-wind sconce cap, part # 58DVA-HSCH or 46DVA-HSCH).
Installation instructions for Simpson Dura-Vent may be found at www.duravent.com.

Vent Installation

Slide the vent sections together and turn 1/4 turn until the sections lock in
place.
Screws are not required to secure the vent. However, three screws may be
used to secure vent sections together if desired.
High temperature sealant is recommended at the appliance starter section
connection (use high-temperature silicone or Mill-Pac®).
If disassembly is required, at time of re-assembly check to see if the vent
creates a tight fit. If it does not, apply high temperature sealant to the joints
of the affected sections.
Horizontal sections require a 1/4" rise every 12" of travel.
Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape).
Travis Industries
Installation
(for qualified installers only)
6-5/8" Diameter Vent
(minimum 12" vertical rise)
Reducer - # 98900165
4140312
23