11. Installation of Light Kit Assembly

11.1
Engage the connector of the light kit assembly with the
motor connector (Figure 23).
The two connectors are keyed and color-coded and must
be mated correctly (color-to-color) before they can be
engaged.
Make sure the connector latch closes properly.
WARNING
!
To avoid possible fire or shock, do not pinch wires
between the light kit assembly and the switch cup plate.
11.2
Remove one switch cup plate screw and retain for future
use. (Figure 24). Loosen the two switch cup plate screws.
Position the light kit assembly notched holes onto the
switch cup plate's two loosened screws.
Rotate the light kit assembly clockwise to engage the two
screws (Figure 24).
Secure the light kit assembly by installing the previous
removed screw (Figure 24).
11.3
Screw the three 60-watt (maximum) candelabra base
bulbs in the light kit assembly sockets (Figure 25).
WARNING
!
Over lamping the fan will result in the lamps being
automatically shut off. Use only 60 watt maximum
candelabra base bulbs. Turn off the electricity before
replacing the bulbs.
WARNING
!
To avoid risk of burns or other injuries, turn power off
and allow lamps to fully cool before attempting to replace
the candelabra base bulbs.
MOTOR
CONNECTOR
LIGHT KIT
ASSEMBLY
CONNECTOR
LIGHT KIT
ASSEMBLY
Figure 23
SWITCH
CUP PLATE
SCREW (3)
LIGHT KIT
ASSEMBLY
Figure 24
ROTATE LIGHT KIT ASSEMBLY CLOCKWISE
LIGHT KIT
ASSEMBLY
SOCKETS (3)
Figure 25
Please contact 1-800-654-3545 for further assistance