Page 1
READ AND SAVE THESE INSTRUCTIONS 42” Model No. CF710AB00 CF710AW00 CF710BS00 CF710PB00 CF710WW00 15.0 Net Weight: Lbs. BUILDER PLUS Series Ceiling Fan Owner's Manual Part No. F40BP72580003 50” Model No. CF711AB00 CF711AW00 CF711BS00 CF711CK00 Net Weight: CF711 shown CF711PB00 CF711WB00 CF711WW00 19.8...
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician. WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage. 1. Check to see that you have received the following...
(Figure 1). NOTE: The setscrews must be properly installed as described above, or fan wobble could result. 5.The fan comes with blue, black and white leads that are 56” long. Measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly.
Installing The Hanger Bracket WARNING The fan must be hung with at least 7' of clearance from floor to blades (Figure 4). Figure 4 FLOOR WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L.
FAN WIRES OMITTED FOR CLARITY. If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture. Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring.
2. Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 9). Securely connect the fan motor black wire and blue wire to the supply black (hot) wire using wire connector supplied (Figure 9).
Figure 13 Removal Of The NOTE: In some instances it may be desirable to install the ceiling fan without the light fixture. If this is the case, proceed as follows. (You may want to keep the light fixture for possible future use.)
3. Check to be sure screws which attach the fan blade flanges to the motor are tight. 4. Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor. 5. Tighten the hanger bracket screws to the outlet box, and/or secure outlet box.
What Will Emerson Electric Co. Do To Correct Problems: Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan.
Repair Parts Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER For repair parts, phone 1-800-654-3545.
Page 12
— — — — — — — — — — BP7258-3 BP7258-3 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 CF711BS00 CF711WB00 CF711CK00 762231-4 762231-5 762231-6 — — — — — —...