Mounting the
Embedded
Caution
Caution
DeviceMaster Installation and Configuration Guide: 2000506 Rev. B
Use the following procedure to mount the DeviceMaster 1-Port Embedded with the 5-
30VDC power supply.
Observe proper ESD techniques when handling the DeviceMaster.
1. Carefully remove the DeviceMaster from the anti-static bag, following standard
electrostatic device handling procedures.
Note: Write down the MAC address located on a label on the bottom (solder side)
center of the DeviceMaster because you may need it during configuration.
2. Mount the DeviceMaster for your environment using 1/4" stand-offs to separate the
DeviceMaster from the base.
5-30VDC Model
1
Non-plated/non-grounded mounting holes 0.116" diameter (+/-0.003").
2
Plated/chassis grounded mounting hole 0.116" diameter (+/-0.003").
3
WARNING: Holes in hatched area are not mounting holes.
4
Maximum component height above board is 0.55".
5
Ethernet connection J2: J2 overhangs board edge by 0.14" and the height is 0.55".
6
Power connector; the mating connector is Weidmuller P/N: 152651.
7
LED light pipe mounting holes. The LED light pipes are not provided.
Serial port connector J3: 0.1" pin spacing, 0.025" square pin diameter, and 0.230"
8
pin height.
9
Debug port connector J4: 0.1" pin spacing, 0.025" square pin diameter, and 0.230"
pin height.
3. Use one of the following methods to ground the DeviceMaster.
Through the power supply by connecting the ground wire on the power cable
using plastic or metal stand-offs.
Through the chassis, using metal stand-offs. If plastic stand-offs are used to
mount the board, then you must ground the DeviceMaster using the power cable.
Note: The maximum diameter of the metal stand-offs should be 0.175" with a 4-40
machine screw. Metal stand-offs are not provided with the DeviceMaster.
4. Optionally, attach the light pipes. The following light pipes have been tested and found
to function; Bivar, Inc. (P/N:LP-230) and Ledtronics, Inc.