Use the following procedure to install the DeviceMaster 16-port or 32-port with an
internal power supply.
1. Record the MAC address and serial number of the DeviceMaster unit on the customer
service label provided.
You may need the MAC address during driver configuration. The serial number and
MAC address (starts with 00 C0 4E) are located on a label on the DeviceMaster.
Note: Do not connect multiple units until you have changed the default IP address, see
Initial Configuration on Page
2. Place the DeviceMaster on a stable surface, or optionally mount the DeviceMaster in a
rack.
Rack Installation:
a.
Attach the L brackets to the interface using the screws supplied with the unit.
b.
You can mount the unit facing in either direction.
c.
Attach the L bracket into your rack.
Follow these guidelines when mounting the DeviceMaster in a rack.
If the DeviceMaster is installed in a closed or multi-rack assembly, the
operating temperature of the rack environment may be greater than the
ambient temperature. Be sure to install the DeviceMaster in an environment
that is compatible with the maximum rated ambient temperature. Refer to
the appropriate link for temperature specifications.
DeviceMaster RTS 16-port:
99455-8
DeviceMaster RTS 32-port:
99456-5
DeviceMaster Serial Hub:
99460-2
Make sure that the mechanical loading is level to avoid a hazardous
condition; such as, loading heavy equipment in the rack unevenly. The rack
should safely support the combined weight of all equipment in the rack.
Slots and openings in the cabinet are provided for ventilation. To ensure
reliable operation of the DeviceMaster and to protect it from overheating,
maintain a minimum of 1 inch of clearance on all sides of the unit.
AC power inputs are intended to be used with a three-wire grounding type
plug, which has a grounding pin. Equipment grounding ensures safe
operation. Do not defeat the grounding means and verify that the
DeviceMaster is reliably grounded when mounting within the rack.
33.
http://www.comtrol.com/products/specifications/
http://www.comtrol.com/products/specifications/
http://www.comtrol.com/products/specifications/
DeviceMaster Installation and Configuration Guide: 2000506 Rev. B