Serial Communications
86 - Hardware Specifications
NS-Link control:
Data bits
Parity
Stop bits
Flow control
Network default values:
IP address
Subnet mask
Gateway
Network protocols
Event notification
SNMP support
Serial Communications
7 or 8
Odd, even, none
1 or 2
Hardware or software
192.168.250.250
255.255.0.0
192.168.250.1
TCP/IP and UDP Socket services,
BOOTP, TFTP, ICMP, ARP, SNMP (MIB-
II), Telnet, HTTP, DHCP/RARP/Ping,
RFC 1006
SocketServer
Monitoring only
DeviceMaster Installation and Configuration Guide: 2000506 Rev. B