8.6 INSTALLING THE CHIMNEY CONNECTOR 
The chimney connector is the single or double wall pipe installed between the stove flue collar and 
the chimney breech. Single wall pipe components are available from most hardware and building 
supply stores. These components are not usually tested to a particular standard and certified as 
compliant. Therefore, a list of rules found in solid fuel installation codes apply to the installation of 
single wall pipe.  
Double wall chimney connectors are tested and certified. The rules for double wall pipe are found 
in  the  manufacturer's  installation  instructions.  These  rules  will  be  very  different  than  those  for 
single wall. 
8.6.1 INSTALLATION OF SINGLE WALL CHIMNEY CONNECTOR 
The  chimney  connector  assembly  has  been  called  'the  weak  link'  in  the  safety  of  wood  heating 
systems because failure to install the connector properly (which has been common in the past) can 
result in house fires.  
The best flue pipe assembly is one that rises straight up from the stove to the base of the chimney 
with no elbows. Straight assemblies are less likely to cause problems like smoke roll‐out when the 
door is opened for loading. They are also more stable and easier to maintain than assemblies with 
elbows.  Horizontal  runs  of  flue  pipe  should  be  avoided  where  possible  because  they  reduce 
chimney draft. 