2200 Installation and Operation Manual
In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment and
the CSA C22.1 Canadian National Electrical Code are to be followed in the absence of local code
requirements. In the USA, the ANSI NFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid
Fuel‐Burning Appliances and the ANSI NFPA 70 National Electrical Code are to be followed in the
absence of local code requirements.
This stove must be connected to a chimney complying with the requirements for Type HT
chimneys in the Standard for Factory‐Built Chimneys for Residential Type and Building Heating
Appliances, UL 103 HT and ULC S629 or to a code‐approved masonry chimney with a flue liner.
7 CLEARANCES TO COMBUSTIBLE MATERIAL
The clearances shown in this section have been determined by test according to procedures set
out in safety standards ULC S627 (Canada), UL1482 (U.S.A.). When the stove is installed so that its
surfaces are at or beyond the minimum clearances specified, combustible surfaces will not
overheat under normal and even abnormal operating conditions.
No part of the stove or flue pipe may be located closer to combustibles than the minimum
clearances given below.
7.1 LOCATION OF THE CERTIFICATION LABEL
Since the information given on the certification label affixed to the appliance always overrides the
information published, in any other media (owner's manual, catalogues, flyers, magazines and/or
web sites) it is important to refer to it in order to have a safe and compliant installation. In
addition, you will find information about your stove (model, serial number, etc.). You can find the
certification label on the back of the stove.
_ _____________________________________________________________________________ 2 7