Factory-Built Metal Chimneys; Masonry Chimneys - Osburn 2200 Installation And Operation Manual

Hide thumbs Also See for 2200:
Table of Contents

Advertisement

  2200 Installation and Operation Manual 
 
8.2.2 FACTORY‐BUILT  METAL  CHIMNEYS 
IN MOBILE HOMES 
For  use  in  a  mobile  home,  this  stove  is  to 
be  connected  to  a  6"  in  diameter  double 
wall  factory  built  chimney  conforming  to 
CAN/ULC‐S629,  Standards  for  650°C 
Factory‐built  chimney.  The  total  length  of 
the  flue  system  should be  at  least 12  feet 
including  elbows,  from  the  top  of  the 
stove.  
To  maintain  an  effective  vapour  barrier, 
insulation  and  waterproof  at  the  chimney 
and  outside  flue  pipe,  install  a  mobile 
home  roof  flashing  and  seal  it  with 
silicone.  
8.2.3 MASONRY CHIMNEYS 
The  stove  may  also  be  connected  to  a 
masonry  chimney,  provided  the  chimney 
complies with the construction rules found 
in  the  building  code  enforced  locally.  The 
chimney must have either a clay liner or a 
suitably  listed  stainless  steel  liner.  If  the 
masonry  chimney  has  a  square  or 
rectangular  liner  that  is  larger  in  cross 
sectional  area  than  a  round  6"  flue,  it 
should  be  relined  with  a  suitably  listed  6" 
stainless  steel  liner.  Do  not  downsize  the 
flue  to  less  than  6"  unless  the  venting 
system  is  straight  and  exceeds  25  feet  in 
height. 
When 
passing 
through 
combustible  wall,  the  use  of  an  insulated 
listed thimble is required. 
  _ _____________________________________________________________________________  3 5 

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ob02211

Table of Contents