(9)
Smear on back
Section Step
Output
1
Toner is spilled over area inside copier.
system
2
Toner is present along the paper path.
3
Right Fusing Roller is dirty, scratchy, or
damaged.
4
Image Transfer Roller is dirty.
5
Grid bias contact is dirty, scratchy,
deformed, worn, or damaged.
Check
Result
YES • Clean interior.
YES • Clean.
YES • Clean or change.
YES • Clean or change.
YES • Clean, correct, or
NO
T-55
Action
change.
• Change High Voltage
Unit (HV1).
• Change Master Board
(copier: PWB-A).