3.6.2 Alarm Input Port

Please refer to the following sheet for more information.
Grounding alarm inputs. Normal open or Normal close type)
Please parallel connect COM end and GND end of the alarm detector (Provide
external power to the alarm detector).
Please parallel connect the Ground of the DVR and the ground of the alarm detector.
Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)
Use the same ground with that of DVR if you use external power to the alarm device.
HDCVI Standalone DVR User's Manual
Figure 3-1
ALARM 1 to ALARM 16. The alarm becomes active in low voltage.
The first four are four groups of normal open activation output (on/off
button)
NO5 C5 NC5 is a group of NO/NC activation output (on/off button)
Control power output. For external alarm, you need to close the
device power to cancel the alarm.
It is external power input. Need the peripheral equipment to provide
+12V power (below 1A).
Earth cable.
485 communication port. They are used to control devices such as
decoder.
They are four-wire double duplex RS485 port
T+ T-: output wire
R+ R-: input wire