Eclipse Security Tribrid User Manual page 36

Table of Contents

Advertisement

SN
Icon
6
VIDEO IN
1~16
7
NO1~NO5
C1~C5
NC5
A
HDCVI Standalone DVR User's Manual
Name
Video input port
Alarm input port 1~16
Alarm output port 1~5
RS485 communication
port
Function
Connect to analog camera to
input video signal.
There are four groups.
The first group is from
port 1 to port 4, the
second group is from
port 5 to port 8, the third
group is from port9 to
port 12, the fourth group
is from port13 to port 16.
They are to receive the
signal from the external
alarm source. There are
two types; NO (normal
open)/NC
close).
When your alarm input
device is using external
power,
please
sure the device and the
NVR have the same
ground.
5 groups of alarm output
ports. (Group 1 : port
NO1 ~ C1,Group 2:port
NO2 ~ C2,Group 3:port
NO3~C3. 4:port NO4~
NO5 ~
C4.
5:port
C5.).Output alarm signal
to the alarm device.
Please make sure there
is power to the external
alarm device.
NO:Normal open alarm
output port.
NC:Normal close alarm
output port.
C:Alarm output public
end.
RS485_A port. It is the cable
A. You can connect to the
control
devices
such
speed dome PTZ.
(normal
make
as
27