Room heating capacity was previously given in accordance with the DIN
18893 standard (last issued August 1987) and is no longer useful for modern
houses built after 1990. However, the old information for room heating
capacity can still be of interest as a comparative value or for use with older
building structures that do not yet correspond to the thermal insulation
standards from 1977.
The nominal heating capacity of the individual fireplace cassettes when
operated as a temporary heating source (meaning with operative intervals of
less than 8 hours) provides the following room heating capacities:
Fireplace
cassette
NHC in KW
Heating
condition
favourable
less favourable
unfavourable
* Significantly larger rooms can be heated with modern thermal insulation
A more precise description for "favourable", "less favourable" and "unfavoura-
ble" can be found in the DIN 18893 standard. In simple terms, "favourable"
represents a situation in which the room only has one exterior wall and is
otherwise surrounded by heated interior rooms, "unfavourable" means, in
contrast, rooms with two exterior walls and adjacent unheated rooms.
The values given above refer to building structures that do not yet correspond
to the requirements of the thermal insulation standards from 1977 and also
represent, therefore, a simplified process that is only valid up to a maximum
room size of 200 m³. The DIN 18893 standard already recommends using
DIN 4701 for these calculations from a room size of 200 m³. It is now
preferable to make an estimate according to TROL or, in particular, to make a
calculation according to DIN 12831.
3.7
Heating in the transitional period / unfavoura-
In the transitional period, meaning when the outside temperature is still high
(above approx. 15°C) or during unfavourable weather conditions (katabatic
winds etc.), it is possible to experience disruption to the chimney flue
performance during sudden rises in temperature so that the hot gasses are
3.6

Room heating capacity

500
600
E4
E5
4,6
4,9
Room heating capacity* during temporary heating (values in m³)
88
88
53
53
34
34
ble weather conditions
framework PAGE - 43 -
700
800
E7
E10
6,9
9,9
165
>186
95
132
65
90
900
E14
14,0
>186
>173
>114