Installation Of The Convection Air Sockets - Spartherm XS 500 Installation And Operating Instructions Manual

Linear fireplace cassettes
Table of Contents

Advertisement

4.
Turn the adjustment screws in the firebox (red arrow, see 2.16)
until they are visible in the firebox.
5.
Take the firebox door off its hinges (see 2.20)
6.
Lift the firebox at the front using 1-2 persons and remove it in a
forwards direction. The positioning rectangle (yellow arrow, see
2.16) must no longer be locked in the opening, only then is it
possible to move the fireplace cassette!
PLEASE NOTE: The firebox must be lifted into the convection air
jacket because the firebox's feet can otherwise cause scratches
to the convection air jacket.
Installation is carried out in the reverse order!

2.19 Installation of the convection air sockets

Fig. 8a
The flow control cover can be reduced in size at the
predetermined breaking point to change the airflow
volume in the pipe system.
In order to install the circulation pipes
(convection air), initially break out the
dummy covers and then screw on the two
sockets as shown (see Fig. 8a) using the
self-tapping screws provided. Alternatively,
these screws can be screwed from the
inside of the convection air jacket outwards.
In order to redirect the airflow volume, the
flaps on the flow control covers at the top
front of the convection air jacket need to be
pushed into the cut-out slots.
framework PAGE - 28 -
Predetermined
point, pre-stressed
Fig. 8b
breaking