Connecting A Hot Air Blower - Spartherm XS 500 Installation And Operating Instructions Manual

Linear fireplace cassettes
Table of Contents

Advertisement

Bend when breaking =>
Without any changes =>

2.20 Connecting a hot air blower

Not valid for linear cassette XS 500!
If the fireplace cassette has been ordered with a hot air blower then you only
need to connect the plug to a properly earthed electricity socket.
The following steps should be carried out for maintenance / inspection of the
hot air blower:
1. Dismantle the cover (see 2.15)
2. Remove the firebox door (see 2.20)
3. Remove the firebox lining (see 2.22)
4. The blower is accessible after the
inclined rear wall has been dismantled.
In order to retrofit a hot air blower, carry out the previously described steps
numbered 1 to 3 and continue with steps 4b to 4g.
4b. Remove the firebox (see 2.17)
4c. Installing the hot air blower involves the following components:
-
connection cable set, blower cable, speed regulator, cylindrical
fan and cable gland
4d. Cut out the pre-cut section of the convection air jacket on the lower left
side using a hand saw. The metal plate can then be broken out of the
convection air jacket. The speed regulator will be positioned in this section at
a later stage.
4e. Now assemble the blower onto the fixing
bracket (see picture) and install it at the
middle / bottom of the convection air jacket.
corresponds to approx. 50% airflow volume
via the connected pipe system and approx.
50% in the installation room.
corresponds to approx 70 % airflow volume
via the connected pipe system and approx.
30% in the installation room.
framework PAGE - 29 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M 700Xl 900S 600L 800

Table of Contents