No combustible construction components, furniture, curtains or decoration
may be placed within a distance of 800 mm (see Fig. 3) of the firebox door in
the thermal radiation field. This distance can be reduced to 400 mm when a
ventilated radiation protection plate is installed between the fireplace and the
combustible elements.
No combustible objects may
be placed within a distance
of
500
mm
fireplace.
2.10 Load-bearing components made of concrete
The fireplace cassette is to be installed in such a way that no load-bearing
construction components made out of concrete or reinforced concrete are
located at the side of the outlet points for the hot air within a distance of 500
mm at the front and up to a height of 50 mm above the outlet points for the
convection air.
2.11 Special safety measures for protecting adja-
cent combustible construction components from
fire (when retrofitting the cassette into a fireplace)
1)
There must be a distance of at least 50 mm between built-in furniture
and the fireplace casing.

2.9.2 Thermal radiation field

above
the
and reinforced concrete
framework PAGE - 21 -