Combustion Air Supply; Combustion Air Pipes; Flow Restrictors; General Requirements For The Use Of Fireplace Cassettes In Existing Fireplaces - Spartherm XS 500 Installation And Operating Instructions Manual

Linear fireplace cassettes
Table of Contents

Advertisement

2.4

Combustion air supply

Fireplace cassettes may only be installed in rooms with at least one door to
the outside or a window that can be opened or are directly or indirectly linked
to a combustion air supply in other rooms. When the cassettes are installed in
apartments or other functional units then only those rooms in the same
apartment or functional unit may be counted as being linked for combustion
air supply purposes.
2.5

Combustion air pipes

According to the state building regulations - which correspond to Article 37,
Paragraph 2 of the Model Building Regulations - combustion air pipes in
buildings with more than two full floors and those pipes that bridge fire walls
must be constructed in such a way that fire and smoke cannot be transferred
to other floors or fire compartments.
PLEASE NOTE:
The guidelines for fire protection requirements in ventilation systems (draft
template) – version January 1984 – can be used to show how the previously
named regulations can be fulfilled.
2.6

Flow restrictors

Flow restrictors may only be installed in exhaust gas sockets or in flue pipes.
Flow restrictors must be easy to operate. They must have openings in the
form of circular sections, which have a continuous area not less than 3% of
the cross-sectional area, and be at least 20 cm² in size. The setting of the
flow restrictor must be identifiable by the position of the operating handle.
2.7
General requirements for the use of fireplace
cassettes in existing fireplaces
The fireplace cassettes are suitable, amongst other things, for retrofitting into
existing fireplaces. Please observe the following installation instructions
before installing the fireplace cassette (read the instructions before starting
the installation of the fireplace cassette and then observe the instructions
during installation):
 Please inform the responsible heating inspector/chimney sweep in
your district before installation.
framework PAGE - 18 -