INSERT INSTALLATION OF THE GAS FIREPLACE

• The framework should rest on top of the fireplace's upper clearance post as well as on the air circulation
boxes located on the sides and at the back of the unit (see section 3.1.3 TOP CLEARANCE.)
• The fireplace can be installed directly on a hard combustible floor (see section 1.2.1) or on a platform with an
appropriate height. Do not place the fireplace on carpeting, vinyl or other soft floor coverings. You can however
install it on wood floor, plywood, particle board or other hard surfaces. Make sure the unit is placed on a
continuous floor or a sturdy platform and that the framework offers adequate support. No cold air should enter
the room from under the fireplace.
WARNING:
No matter the vent system configuration you choose, you must absolutely install an insulating sleeve over
the first 8 ft. of vent, no exception. Always use the firestop provided with the gas fireplace when the vent is
protected by the 8 ft. insulating sleeve and it goes through a wall/floor/ceiling/etc.
3.1.1

DRAWINGS OF MINIMUM CLEARANCES FOR INSTALLATION

3.1.1.1

LOO / RGR-25 (INSERT) WITH BACK EXIT

21