Note: The gas line connection can be made of a 3/8 in. (12 mm) rigid tube or an approved flexible connector. It
is possible that other codes apply in your area. Please consult local authorities and the National Fuel Gas Code
ANSI.z223.1, NFPA54 in force. In Canada, consult the CAN/CGA-B149 (1 or 2).
Note: It is strongly recommended to plan for a 12 in. minimum additional length of gas pipe inside the fireplace
(under the combustion chamber) to make
to disconnect the gas supply to work on the
6.3

INSTALLATION CODE

IMPORTANT
Install the main gas valve (stop valve) in an accessible location. The valve allows you to block the fireplace's
gas intake. Check building codes specifications regarding the location of the manual gas valve.
CAUTION
Use a propane gas-resistant joins sealant (metallic compound) to secure your gas lines.
Apply a light coat of joint sealing compound (metallic compound). Make attention to do not put excess sealant.
Excess sealant compound in pipes can lead to clogging the burner system.
We recommend installing a sediment trap in the supply line (figure 6.2). Install it where residues are not likely to
freeze. A sediment trap is designed to trap moisture and contaminants to prevent them from reaching the gas
burner control system.
6.4

GAS PRESSURE

Ideal intake
pressure
Min. Intake
pressure
Max. Intake
pressure
• It is essential to use the type of gas specified on the nameplate of the unit. In case of discrepancy, STOP
EVERYTHING and contact your merchant to get a
• To make installation easier, a 12 in. (30 cm) flexible duct equipped with a manual valve is supplied with the
appliance. Install the 3/8 in. (12 mm) supply line and fasten it to the shutoff valve.
• Once gas line installation is completed, purge gas lines and check that all connections as well as the gas meter
(or tank) connected to the fireplace are tight. Make sure there are no leaks (see section 6.6).
• To adjust flame height, turn the HI/LO control knob located on the automatic valve.
WARNING:
Never use an open flame to check for gas leaks.
SmartCase
®
maintenance easier. This way, the technician will not have
SmartCase
®
.
Natural gas (NG)
7" w.c. / 1.74 kPa
3.5" w.c. / .87 kPa
10.5" w.c. / 2.61 kPa
SmartCase
11" w.c. / 2.8 kPa
8" w.c. / 1.99 kPa
13" w.c./3.23 kPa
®
that matches the type of gas you are using.
Propane (PG)
52