Burner Removal; Burner Installation - J. A. Roby SUROIT / RGV-25 Installation And Operation Manual

Direct-vented gas fireplaces
Hide thumbs Also See for SUROIT / RGV-25:
Table of Contents

Advertisement

3.6

BURNER REMOVAL

• Remove the door as described in section 8.3.1.
• Unscrew the screw located on the left of the burner (figure 3.6).
• Move the burner completely to the left to remove the
hose from the air/gas mixture box and lift it vertically.
3.7

BURNER INSTALLATION

To install the burner, place it completely on the left of the empty space located on the floor of the combustion
chamber. Then slide it to the right until the gas supply pipe fits into gas/air premix box of the
(figure3.7.a). Make sure the pilot is aligned with the notch in the burner (figure 3.7.b). Once the burner is in place,
screw it in (figure 3.6)
WARNING:
For optimal combustion, you must place the mandatory required amount of glass (2 cups) on the burner.
Figure 3.7.a
SmartCase
Figure 3.7.b
®
42

Advertisement