WARNING:
Connection of gas lines to the appliance must be performed by a certified installer. Observe all local
installation codes.
CAUTION:
Never connect the gas line directly to the fireplace operating on propane (LPG) or natural gas (NG). This
system requires an external regulator (not supplied). Install the external regulator directly on the cylinder and
adjust the pressure according to the table featured in section 6.4.
6.2

INSTALLATION EQUIPMENT REQUIRED FOR GAS LINES

Make sure you have on hand the following items before installing the fireplace:
An external regulator. The installer must supply an external regulator for propane/LPG connection. The
purpose of the regulator is to reduce incoming gas pressure (Table 6.4). If intake pressure is not adjusted
SmartCase
properly, the
A pipeline network (check local codes).
CSA approved gas lines sealant.
A manual valve has to be placed inside the lower compartment of the appliance (before
6.2).
A pressure gauge connection.
A sediment trap (recommended) (figure 6.2).
An approved flexible gas line equipped with a connector (figure 6.2).
Figure 6.2
WARNING
Connection must be performed by a certified installer.
CAUTION
A manual shut-off valve must be installed before the
®
' automatic valve could be damaged (see section 6.4).
SmartCase
®
. It must be easy to access(see figure 6.2).
®
SmartCase
) (figure