932 Tab (SPA962 only)

Unit 1

Field
Unit 1 Key 1-32
Linksys IP Phone Administrator Guide
5-52
Description
This field lets you enter a string that defines the extension and other parameters associated
with each lighted button on the first SPA932 unit. Keywords and values are case-sensitive.
The configuration script is composed of the following keywords, followed by an equal
sign (=) and separated by semicolons (;):
fnc—defines which of the following functions are enabled for the specified key
(separate more than one function with a plus sign (+):
blf—busy lamp field function used for monitoring line activity
sd—speed dial function
cp—call pickup (if supported by the SIP proxy server)
sub—Use this keyword to identify the phones to be monitored.
usr —Use this keyword to identify the specific users or extensions to be monitored.
nme—(optional) Use this field with the SPA9000 to identify any alias that has been
assigned to the extension in the Linksys IP phone configuration.
vid—(optional) Use this field to identify the SPA962 extension to use with the
monitored list specified by the sub= keyword, when more than one BLF monitored
list is configured on the SIP proxy server. The possible values are 1 to 6,
corresponding to each of the six extensions available on the SPA962.
You only need to use the vid= keyword in the first entry assigned to each
Note
SPA962 extension. Subsequent keys will use the same extension.
The following is the syntax for a Broadsoft server:
fnc=enabled_functions;sub=blf_list_uri@broadsoft;usr=dn@broadsoft
Replace the variables (in italics), as follows:
enabled_functions with cp for call pickup, sd for speed dial, and blf for busy lamp
field; separate multiple functions in any order with a plus sign (+)
blf_list_uri
with the URI assigned to the BLF monitoring list on the Broadsoft
server.
broadsoft
with the IP address or hostname of the Broadsoft server.
dn
with the number associated with the user account on the Monitored Users list.
For example:
fnc=sd+blf;sub=marketing@192.168.100.1;usr=reception@192.168.100.1
Note
The nme keyword is not used because the Broadsoft server automatically uses the
assigned user account name.