932 Tab (SPA962 only)
Unit 1
Field
Unit 1 Key 1-32
Linksys IP Phone Administrator Guide
5-52
Description
This field lets you enter a string that defines the extension and other parameters associated
with each lighted button on the first SPA932 unit. Keywords and values are case-sensitive.
The configuration script is composed of the following keywords, followed by an equal
sign (=) and separated by semicolons (;):
•
fnc—defines which of the following functions are enabled for the specified key
(separate more than one function with a plus sign (+):
blf—busy lamp field function used for monitoring line activity
–
sd—speed dial function
–
–
cp—call pickup (if supported by the SIP proxy server)
•
sub—Use this keyword to identify the phones to be monitored.
•
usr —Use this keyword to identify the specific users or extensions to be monitored.
•
nme—(optional) Use this field with the SPA9000 to identify any alias that has been
assigned to the extension in the Linksys IP phone configuration.
•
vid—(optional) Use this field to identify the SPA962 extension to use with the
monitored list specified by the sub= keyword, when more than one BLF monitored
list is configured on the SIP proxy server. The possible values are 1 to 6,
corresponding to each of the six extensions available on the SPA962.
You only need to use the vid= keyword in the first entry assigned to each
Note
SPA962 extension. Subsequent keys will use the same extension.
The following is the syntax for a Broadsoft server:
fnc=enabled_functions;sub=blf_list_uri@broadsoft;usr=dn@broadsoft
Replace the variables (in italics), as follows:
enabled_functions with cp for call pickup, sd for speed dial, and blf for busy lamp
•
field; separate multiple functions in any order with a plus sign (+)
blf_list_uri
with the URI assigned to the BLF monitoring list on the Broadsoft
•
server.
broadsoft
•
with the IP address or hostname of the Broadsoft server.
dn
with the number associated with the user account on the Monitored Users list.
•
For example:
fnc=sd+blf;sub=marketing@192.168.100.1;usr=reception@192.168.100.1
Note
The nme keyword is not used because the Broadsoft server automatically uses the
assigned user account name.
Chapter 5
Linksys IP Phone Field Reference
Firmware Version 5.1