Alarm In; Alarm In Setting - Huviron SK-V207IR-Z946 User Manual

Ir speed dome camera
Table of Contents

Advertisement

4.5 ALARM IN(Path : MAIN MENU / ALARM IN)
This function is to activate alarm upon detection of sensor.

4.5.1 ALARM IN SETTING

1) Sensor Num :
for alarm input.
2) Priority :
Set the priority of 8 alarm inputs and react to the alarm input in accordance
with the priority.
Lower number means higher priority. Operation by the alarm with higher priority
takes precedence over the alarm with lower priority. In case of the alarms with the
same priority, the camera would be operated by the latest alarm in. On operating
by the alarm with higher priority, the alarm with lower priority would be ignored.
3) Input Contact :
ㆍOff :
No sensor connected.
ㆍN.O :
Normally Open.
ㆍN.C :
Normally Close.
<Caution> In case there is no sensor connected, Please set "OFF", otherwise it might cause
malfunction.
4) Activate :
Set "On" to activate "ALARM OUT", "PRESET" or "DOME ACTION". Operation
by "PRESET " would be just one time, and after that, operation by "DOME ACTION"
would repeat .
ㆍAUX :
Enables selecting an alarm output method.(Off/1/2) Off is not support alarm
output. 1 is Relay. 2 is Open collector.
ㆍPreset :
Enables setting up a Preset action.
ㆍDome Action :
Chapter 4. Menu configuration and operating

ALARM IN ----------------------------------

Sensor Num:
Priority:
Input Contact:
Activate
├ AUX:
├ Preset:
└ Dome Act:
Set
Back
Exit
[Menu 4-19] Alarm In Menu
Set the alarm numbers up to 8. Please refer to Terminal configuration
Set according to the connected sensor.
Enables setting up a Dome action.
1
1
Off
Off
Off
Off
36