Operating the Override

Operating the Key Override, See Section H.
Note: If the lock will not respond to any code, there are three options that
should be attempted to open the door. In order, they are:
1. Verify the batteries, and replace them if they are providing less than 4
Volts total.
2. Use the electronic override feature (requires maintenance unit and
communication cable). Refer to maintenance unit user guide.3. Contact
Technical Support for instructions on using the drill point.

Deadbolt Deactivation:

A. Deadbolt Deactivation by Thumbturn
While standing inside the room, close the door and then turn the thumbturn to
extend the deadbolt. (If the lock has an autodeadbolt mortise, go to step B
below).
Turn the thumbturn to retract the deadbolt. Repeat.
B. Deadbolt Deactivation by Lever
While standing inside the room, close the door and turn the thumbturn to
the horizontal position to extend the deadbolt (or to select privacy on
autodeadbolt models). Open the door by turning the lever. The deadbolt
and the latch bolt retract simultaneously and fully. Take note of any
excess friction, which might necessitate filing the strike (deadbolt area
only). Repeat.