DMX Data Cabling
DMX data cables: Belden
applications) with characteristics listed below:
•
2-conductor twisted pair plus a shield
•
maximum capacitance between conductors - 30 pF/ft.
•
maximum capacitance between conductor and shield - 55 pF/ft.
maximum resistance of 20 Ω/1000 ft.
•
nominal impedance 100–140 Ω
•
•
22–24 AWG with insulation having a dielectric rating of 300 volts or higher
DMX data connectors:
DMX data terminators:
Test Standards
Ecodome conforms to the following standards:
•
UL 1572
•
EN 60598-1
•
CSA 22.2 No. 9
•
EMC standards:
•
EN 55022, Class A ITE
•
IEC 801-2, Level 3 (6/8kV)
•
IEC 801-3, Level 2 (3 V/m)
•
IEC 801-4, Level 2 (1kV/.5kV)
•
ENV 50204, 1996 Level 2 (3 V/m)
Safety
•
Maximum ambient temperature (T
•
Maximum exterior surface temperature: 62° C (144° F).
•
Suitable for mounting on normally flammable surfaces.
•
Not for residential use.
®
Ecodome
User Manual
®
9841 or equivalent (meets specifications for EIA RS-485
3-pin male and female XLR connectors
male XLR connector with 120 ohm terminator
): 40° C (104° F).
a
Introduction intro-3